Adjustment - Sharp CD-C602 Service Manual

Hide thumbs Also See for CD-C602:
Table of Contents

Advertisement

MECHANISM SECTION
• Driving Force Check
Torque Meter
Play: TW-2412
• Torque Check
Torque Meter
Play: TW-2111
30 to 60 g. cm
Fast forward: TW-2231
80 to 135 g.cm
Rewind: TW-2231
80 to 135 g.cm
• Tape Speed
Test Tape
Adjusting
Point
Normal
MTT-111
Volume in
speed
motor
TAPE MECHANISM
Volume in motor
Figure 9-1 ADJUSTMENT POINTS
AM IF
T351
TP303
IC351
21
13
TP301
+
VR351
T352
VCO
FM Detection
TP302
MAIN PWB
Figure 9-2 ADJUSTMENT POINTS
All manuals and user guides at all-guides.com

ADJUSTMENT

Specified Value
Tape 1: Over 100 g
Tape 2: Over 50 g
Specified Value
Tape 1
Tape 2
30 to 60 g.cm
Specified
Instrument
Value
Connection
3,000 ±
Speaker
30 Hz
terminal
(Load
resistance:
4 ohms)
AM Tracking fL
AM Band
Coverage fL
T333
FM Band
Coverage fL
T331
L303
T301
CNP301
FM/AM
ANTENNA
FM IF
TERMINAL
1
IC301
L302
FM RF
L301
TUNER SECTION
fL: Low-range frequency
fH: High-renge frequency
• AM IF/RF
Signal generator: 400 Hz, 30%, AM modulated
Test Stage Frequency
IF
450 kHz
Band
Coverage
Tracking
990 kHz
*1. Input: Antenna (CNP301), Output: TP302
*2. Input: Antenna (CNP301), Output: TP301
• FM RF
Signal generator: 1 kHz, 22.5 kHz dev., FM modulated
Frequency Frequency
Test Stage
Band
Coverage
RF
98.00 MHz 98.00 MHz L302
(10-30 dB)
*1. Input: Antenna (CNP301), Output: TP301
*2. Input: Antenna (CNP301), Output: Speaker terminal
• FM Detection
Signal generator: 10.7 MHz, FM sweep generator
Test
Frequency
Frequency
Stage
Detection 10.7 MHz
98.00 MHz T352
IF
10.7 MHz
98.00 MHz T301(Turn
• VCO Frequency
Frequency
Frequency
Display
98.00 MHz
98.00 MHz
(60 dB)
* Adjust for 76 kHz ± 200 Hz.
Notes:
After preparing the test circuit shown in Fig 9-3, connect the
Pin 13 , Pin 21 and ground of the IC351 with test circuit, and
measure the Value.
At this time, apply a standard unmodulated signal input and
adjust the VCO.
Pin 13 of IC351
Pin 21 of IC351
FET : 2SK19 or 2SK54
D
G
S
10 kohm
– 9 –
CD-C602,CP-C602
Frequency
Setting/
Instrument
Display
Adjusting
Connection
Parts
1,720 kHz
T351
*1
530 kHz
(fL): T333
*2
1.1 ± 0.1 V
990 kHz
(fL): T331
*1
Serring/
Instrument
Display
Adjusting
Connection
Point
87.50 MHz L303(fL):
*1
1.3 V ± 0.1 V
*2
Adjusting
Instrument
Display
Parts
Connection
Input: Pin 1 of
IC301
Output: TP302
Input: Pin 1 of
the core of
IC301
transformer Output: TP302
T352 fully
counter-
clookwise.)
Adjusting
Instrument
Parts
Connection
VR351*
Pin 13, Pin 21
and ground
of IC351
TO FREQUENCY
COUNTER
Figure 9-3