Siemens CCMX1315-LP Configuration Manual page 45

1/3” 1.3 megapixel ccd colour ip camera
Table of Contents

Advertisement

Siemens Building Technologies
Fire Safety & Security Products
Scheduled Recording
Determine the recording condition: STOP, all day, schedule 1 or schedule 2 from
the recording schedule table for all days from Monday to Sunday.
Recording by Alarm
Configure "Alarm input setting" first.
Then select the recording format:
Record source: choose JPEG or MPEG4 format
Recording frame
Set the number of images to be recorded immediately after an alarm occurs.
Images of the moment when an alarm occurs are not included.
1, 2, 5, 10, 30 and 60 frames can be selected if JPEG format selected. No
need for MPEG4 format
Recording cycle
Set a time interval for alarm recording 1, 2, 5, 10, 30, 60, 90, 120 s can be
selected for JPEG format, no need for MPEG4 format
Recording time:
If MPEG4 is selected, please set the recording time to 2, 5, or 10 s.
Recording by Motion
Configure "Motion Detection Setting" first.
All the other settings are same as recording by alarm as above.
NOTE
Make sure all NAS devices are ready on the network before activating this function.