External Digital Input 1; External Digital Input 2 - Siemens CCMX1315-LP Configuration Manual

1/3” 1.3 megapixel ccd colour ip camera
Table of Contents

Advertisement

Configuration
7.4.1

External digital input 1

7.4.2

External digital input 2

34
Siemens Building Technologies
Fire Safety & Security Products
Set an "Alarm Input"
ON: Detects an external alarm.
OFF: Does not perform alarm detection.
The following functions will be enabled if " Alarm Input" is set to "ON"
Set "Input type" for alarms
Normally Open (NO): A dry-contact detecting way, opened if nothing occurs but
closed in case of an alarm.
Normally Closed (NC): A dry-contact detecting way, closed if nothing occurs but
open in case of an alarm.
Set "TEXT Enable" for alarms
A noticeable message of alarm can be displayed on screen if this item is set to
"ON".
Enter "Text" for alarm message
Max 24 characters can be entered.
Set "Audio out" for alarm message
An audio alarm message can be sent to an external speaker if this item set to
"ON".
NOTE
A speaker with integrated amplifier can be connected to the AUDIO out jack on the rear panel.
Select "EVENT"
Pre-recorded voice files with extension .wav that have been uploaded to SD
memory card in advance can be selected as voice alarm message. Up to 4 kinds
of audio source can be selected.
All configurations are the same as for Alarm digital 1, except that an additional
input mode – enforced BW – is added, which will switch the camera to
monochrome mode if a trigger signal is received.
01.2009