RS-232C Configurations

4P Cable

4-Wire Configurations (Standard RS-232C cable)
RXD
TXD
GND
IR
NOTE
When using three-wire connections (non-standard), an IR daisy chain cannot be used.
If you want to control multiple units simultaneously, use 3.5 mm 4-pole cables (sold separately).

RS-232C Cable

8-Wire Configurations (Standard RS-232C cable)
PC
DCD
1
RXD
2
TXD
3
GND
5
DTR
4
DSR
6
RTS
7
CTS
8
D-Sub 9
D-Sub 9
(Female)
(Female)

Communication Parameter

Baud Rate : 9600 BPS
Data Length : 8 bit
Parity Bit : None
Stop Bit : 1 bit
Flow Control : None
Communication Code : ASCII code
Use a crossed (reverse) cable
TXD
RXD
GND
IR
RS-232C
Gender
1
DCD
3
TXD
2
RXD
5
GND
6
DSR
4
DTR
8
CTS
7
RTS
35