Intelligent data transfer device for connection to plcs and modbus networks
Table of Contents

Advertisement

3
Starting the Software
3.
Type in a name for the project up to eight letters
and numbers in the Project Name: field and press
Enter. The Project Type: field will then be high-
lighted. Press the spacebar to display the project
types, which are:
PLCs to Devices—allows a PLC to control
and/or monitor up to 32 supported Siemens
devices. See Chapter 4 for configuring this
project type.
10
Modbus Master to Devices—allows a Mod-
bus speaking host system, personal com-
puter running SCADA software, or PLC to read
and write registers in up to 32 supported Sie-
mens devices. See Chapter 5 for configuring
this project type.
SEAbus Port Expander—allows two Siemens
ACCESS supervisory computers to connect
up to 32 Siemens ACCESS devices. See
Chapter 6 for configuring this project type.
Siemens Energy & Automation, Inc.