SITRANS P measuring instruments for pressure
Transmitters for gage, absolute and differential pressure, flow and level
DS III series
for gage pressure
Selection and Ordering data
SITRANS P pressure transmitters for gage
pressure, series DS III HART
Measuring cell filling
2
Silicone oil
1)
Inert liquid
Span
0.01 ... 1 bar g
0.04 ... 4 bar g
0.16 ... 16 bar g
0.63 ... 63 bar g
1.6 ... 160 bar g
4.0 ... 400 bar g
7,0 ... 700 bar g
Wetted parts materials
Seal diaphragm
Stainless steel
Hastelloy
Hastelloy
Version as diaphragm seal
Process connection
• Connection shank G½B to EN 837-1
• Female thread ½-14 NPT
• Oval flange made of stainless steel
7
- Mounting thread
- Mounting thread M10 to DIN 19213
- Mounting thread M12 to DIN 19213
• Male thread M20 x 1,5
• Male thread ½-14 NPT
Non-wetted parts materials
• Housing made of die-cast aluminium
• Housing stainless steel precision casting
Version
• Standard version
• International version, English label inscriptions,
documentation in 5 languages on CD
Explosion protection
• Without
• With ATEX, Type of protection:
- "Intrinsic safety (EEx ia)"
- "Explosion-proof (EEx d)"
- "Intrinsic safety and explosion-proof enclosure
6)
(EEx ia + EEx d)"
- "Ex nA/nL (zone 2)"
- "Intrinsic safety, explosion-proof enclosure and
dust explosion protection (EEx ia + EEx d +
6)
Zone 1D/2D)"
• With FM + CSA, Type of protection:
- "Intrinsic safety and explosion-proof
5)
(is + xp)"
Electrical connection / cable entry
• Screwed gland Pg 13.5 (adapter)
• Screwed gland M20x1.5
• Screwed gland ½-14 NPT
• Han 7D plug (plastic housing) incl. mating
7)
connector
• M12 connector (metal)
2/74
Siemens FI 01 · 2009
Order No.
7 M F 4 0 3 3 -
7 7 7 7 7
Measuring cell
cleaning
}
1
Standard
3
Grease-free
}
B
(0.15 ... 14.5 psi g)
}
C
(0.58 ... 58 psi g)
}
D
(2.32 ... 232 psi g)
}
E
(9.14 ... 914 psi g)
}
F
(23.2 ... 2320 psi g)
}
G
(58.0 ... 5802 psi g)
}
J
(102.0 ...10153 psi g)
Process connection
}
Stainless steel
Stainless steel
Hastelloy
2) 3)
}
/
-20 UNF to EN 61518
16
}
4)
}
5)
}
7)
}
8)
© Siemens AG 2008
Selection and Ordering data
SITRANS P pressure transmitters for gage
pressure, series DS III HART
-
7 7 7 7
Display
• Without indicator
• Without visible digital indicator (digital indicator
hidden, setting: mA)
• With visible digital indicator, setting: mA
• with customer-specific digital indicator
(setting as specified, Order code "Y21" or "Y22"
required)
}
Available ex stock
Power supply units
amplifiers".

Factory-mounting of shut-off valves and valve manifolds see page

2/142.
Included in delivery of the device:
A
• Brief instructions (Leporello)
B
• CD-ROM with detailed documentation
C
1)
For oxygen application, add Order code E10.
Y
2)
When the manufacture's certificate M (calibration certificate) has to be
ordered for transmitters with diaphragm seals, it is recommended only to
order this certificate exclusively with the diaphragm seals. The measuring
0
accuracy of the total combination is certified here.
1
3)
Whe the acceptance test certificate 3.1 for transmitters with direct-con-
nected diaphragm seals is ordered, this certificate must also be ordered
2
with the corresponding seals.
4)
Not together with Electrical connection „Screwed gland Pg 13.5" and
3
„Han7D plug".
4
5)
Without cable gland, with blanking plug
5
6)
With enclosed cable gland EEx ia and blanking plug
6
7)
Not together with type of protection "Explosion-proof" and type of protection
"Ex nA".
8)
Cannot be used together with the following types of protection:
0
"Explosion-proof" and "Intrinsic safety and explosion-proof"
3
1
2
A
B
D
P
E
R
N C
A
B
C
D
F
Order No.
7 M F 4 0 3 3 -
7 7 7 7 7
}
see "SITRANS I power supply units and isolation
-
7 7 7 7
0
1
6
7