  • Page 1 Service Manual Wall-Mounted Front-Load Washer MINI DWM30-999PG DWM30-999PG(영_SM).indd 1 16. 8. 23. 오전 10:10...
  • Page 2: Table Of Contents

    1. What is Wall-Mounted Front-Load Washer MINI? .......... 2 2. Specifications ....................4 3. Assembly Part List .................... 5 4. PCB Functions ....................13 5. Wiring Diagram ....................27 6. Part List and Major Specifications ..............28 7. Installation ....................... 45 DWM30-999PG(영_SM).indd 1 16. 8. 23. 오전 10:10...
  • Page 3: What Is Wall-Mounted Front-Load Washer Mini

    2. Features of Wall-Mounted Front-Load Washer MINI Spoon-Shaped Detergent Container Containers for detergent and softener are discretely designed to prevent mixture. The spoon-shaped design enables you to apply the proper amount of detergent conveniently. DWM30-999PG(영_SM).indd 2 16. 8. 23. 오전 10:10...
  • Page 4 As the Normal cycle takes only 29 minutes, it speeds up the laundry process and reduces water and power consumption by 64% compared to regular front-load washers. 3. Baby Clothes Cleaning (DWM30-999PG) Mini's 'Baby Care' cycle enables a complete steam wash and rinse function to protect sensitive baby skin from irritation.
  • Page 5: Specifications

    550mm x 600mm x 302mm(W x H x D) Weight 16.5KG Standard Volume Power 220~240V DWM30-999PG/ODW30-999G, Wash 100W ODW30-999B Power Consumption Heating 1400W D-CV701PC**/AW** Wash 2.5KG Load Spin 2.5KG Washer Type Front Load Installation Mounted on Wall Water Pressure 98.1KPA~784KPA (1KGf/cm²~8KGf/CM2) DWM30-999PG(영_SM).indd 4 16. 8. 23. 오전 10:10...
  • Page 6: Assembly Part List

    3. Assembly Part List 1. TUB AS DWM30-999PG(영_SM).indd 5 16. 8. 23. 오전 10:10...
  • Page 7 361NPCB942 MINI,V.E,220,J,COLD+HEATER-O,NO-EMI(PERU,ARAB) 361NPCB943 MINI,V.E,220,J,COLD+HEATER-O,EMI(RUSSIA) 361NPCB944 MINI,V.E,220,J,COLD+HEATER-O,EMI(KOR) 361NPCB945 MINI,V.E,220,J,COLD+HEATER-X,EMI(KOR),0.5W 361NPCB946 MINI,V.E,220,J,COLD+HEATER-X,NO-EMI(PERU,ARAB) A31 MAIN PCB AS 361NPCB947 MINI,V.E,220,J,COLD+HEATER-O,EMI(CHINA) 361NPCB948 MINI,220,J,COLD+HEATER-O,EMI(CHINA) 361NPCB949 MINI,V.E,220,J,COLD+HEATER-O,EMI,0.5W(E.U) 361NPCB94A MINI,V.E,220,J,COLD+HEATER-X,EMI(KOR) 361NPCB94B MINI,V.E,220,J,COLD+HEATER-O,EMI(BRAZIL) 361NPCB94C MINI,V.E,110,J,COLD+HEATER-O,EMI(BRAZIL) 361NPCB94D MINI,V.E,110,J,COLD+HEATER-O,NO-EMI(PANAMA) A32 REACTOR 3615800500 RT-028 L=3.6MH(0A),L=5.2MH(1A) OPTION DWM30-999PG(영_SM).indd 6 16. 8. 23. 오전 10:10...
  • Page 8 REMARK CLAMP GASKET AS 3611204540 D-M300, D1.4 GASKET DOOR 3612328000 D-M300,EPDM PACKING DETERGENT PRPKCA3R80 D-M300, NBR COVER TUB 3618831700 D-M300, FRPP SCREW TAPPING 7122502508 T2S TRS 5*25 SUS GASKET TUB 3612326100 D-M300, PI=4.5,EPDML=1385 DWM30-999PG(영_SM).indd 7 16. 8. 23. 오전 10:10...
  • Page 9 36109-0002311 ABS (WH1404A), MINI 1.5 PET, WFWM122C0NN01BCCX(DWM30- DECORATOR FILM 36167-0076500 999PG) MINI 1.5-PJT PCB AS PRPSSWD100 D-M301 FRONT PCB AS, H/T DL-S2,DM. 250V16A.BITRON. SWITCH DOOR LOCK 3619047230 VE-TYPE,CONCORE CASE PCB F 36111T3L03 D-M300 HIPS V0 DWM30-999PG(영_SM).indd 8 16. 8. 23. 오전 10:10...
  • Page 10 D-M300, ZNDC HOOK SPRING, SUS304 D1.4, L36.6, HOOK SPRING 36130-0001801-00 D-M300 PIN HANDLE 3618200201 SWCH1018A+HEAT+GILT, D3, L48 FRAME DOOR O 36121-0021300 ABS 419*397*26 1 MINI 1.5 SCREW TAPPING 7122401411 T2S TRS 4X14 MFZN DWM30-999PG(영_SM).indd 9 16. 8. 23. 오전 10:10...
  • Page 11 5. BODY AS PART NAME PART CODE DESCRIPTION Q’TY REMARK BODY AS 36104-0001811 36104-0001811 BODY AS BODY 36104-0001812 36104-0001812 DWM30-999PG(영_SM).indd 10 16. 8. 23. 오전 10:10...
  • Page 12: Dtiii-2P-05 250V 16A,H05Vv-F 3X1.5,3M,Euro

    CUSHION PAD 3611535360 D-M300, EPDM 3T ID=10, OD=70 SCREW TAPPING 7115401629 T1 FLT 4X16 SUS MANUAL OWNERS 3613926450 D-M300 INSTALL GUIDE 3612513000 D-M300 USER INSTALL GUIDE 3612513020 D-CV701 FILTER INLET AS 3615418550 D-M300,1/4",POM DWM30-999PG(영_SM).indd 11 16. 8. 23. 오전 10:10...
  • Page 13 AUC0404W 1/4' DMT TEE UNION 3612512820 D-M300, ATU0404W 1/4' DMT 36131-0010301 D-M300, HOOK TYPE ADAPTER INLET VALVE AS 36131-0010401 D-M300, SCREW TYPE INSTALL GUIDE 3612513000 D-M300 ANCHOR BOLT AS 3616067200 3/8"(M10),SUS,L=8"/OPTION, P/W 2T 30MM,LOCK NUT DWM30-999PG(영_SM).indd 12 16. 8. 23. 오전 10:10...
  • Page 14: Pcb Functions

    400RPM and 500RPM apply to the Delicate and Night Time cycles, respectively. 3. The drainable water must be 45°C or colder. 4. As many as 5 additional rinse cycles are available for all programs. DWM30-999PG(영_SM).indd 13 16. 8. 23. 오전 10:10...
  • Page 15 Delicate and Night Time cycles. 400RPM and 500RPM apply to the Delicate and Night Time cycles, respectively. 3. The drainable water must be 45°C or colder. 4. As many as 5 additional rinse cycles are available for all programs except the Intensive. DWM30-999PG(영_SM).indd 14 16. 8. 23. 오전 10:10...
  • Page 16 Up to 5 additional cycles are available for 'QUICK 15' * In case of Regular Model : Up to 6 cycles are available for 'Delicate' The LED lamp for 'Program' button flickers duringand remains Start/Pause on when the washer stops the cycle. DWM30-999PG(영_SM).indd 15 16. 8. 23. 오전 10:10...
  • Page 17 - Start the pump on the occurrence of the "E4" error. 4 If the water level is below the reset level during the resupply of water, the 'IE' error is displayed and the heater is turned off. DWM30-999PG(영_SM).indd 16 16. 8. 23. 오전 10:10...
  • Page 18 5) Water Level for Heating Cycle 1 If the water level is measured below the preset level, the heater is turned off to prevent overheating or short circuit during the heating cycle. DWM30-999PG(영_SM).indd 17 16. 8. 23. 오전 10:10...
  • Page 19 1 It is equivalent to the drainage cycle for rinsing. 2-3.Spin Cycle 1) Termination of Door Lock 1 After the electric signal to door lock is cut off, the door is shaken horizontally until it becomes mechanically openable. DWM30-999PG(영_SM).indd 18 16. 8. 23. 오전 10:10...
  • Page 20 : Water level to start draining water due to overflow risk. The water supply is suspended and water is drained to lower the level to the reset level if the overflow level is reached. DWM30-999PG(영_SM).indd 19 16. 8. 23. 오전 10:10...
  • Page 21 3 The Child Lock mode is terminated if the 'Program' and 'Add Rinse' buttons are pressed simultaneously. 4 If the Power button is pressed for over 1.5 seconds, the Child Lock mode is terminated. DWM30-999PG(영_SM).indd 20 16. 8. 23. 오전 10:10...
  • Page 22 Number of errors in DC LINK low voltage 'b7', 'number' Number of failures in starting motor 'b8', 'number' Operate the cold water valve Operate the softener valve Operate the drainage valve 'dr' Unlock the door 'LC', 'LO' DWM30-999PG(영_SM).indd 21 16. 8. 23. 오전 10:10...
  • Page 23 2 The error disappears promptly when the door is closed and the subsequent cycle starts. 2) The "LE" error flickers on the display panel. 3) If the Power button is turned off and on, the error display disappears. DWM30-999PG(영_SM).indd 22 16. 8. 23. 오전 10:10...
  • Page 24 2) The "E9" error flickers on the display panel. 3) The error warning is sounded for 10 seconds every 10 minutes. 4) If the Power button is turned off and on, the error display disappears. DWM30-999PG(영_SM).indd 23 16. 8. 23. 오전 10:10...
  • Page 25 Number of failures in tracking the motor speed 'b6', 'number' Number of errors in DC LINK overvoltage 'b7', 'number' Number of errors in DC LINK low voltage 'b8', 'number' Number of failures in starting motor DWM30-999PG(영_SM).indd 24 16. 8. 23. 오전 10:10...
  • Page 26 1 The water temperature rises by 6°C or more within 30 seconds after the heater starts running due to the lack of water in tub or other reasons. 2 The water heater doesn't operate although it is functional. The washer is running with the heater turned off. DWM30-999PG(영_SM).indd 25 16. 8. 23. 오전 10:10...
  • Page 27 1: W 2: V ⑧ WF2(BLUE 2PIN) ② WF9(BLACK 4PIN) 3: U REACTOR OPTION 1: Vdd 2: GND ⑤ WF6(WHITE 2PIN) : 3: LEVEL SENSOR HEATER OPTION 4: W-TEMP 1: HEATER 2: HEATER DWM30-999PG(영_SM).indd 26 16. 8. 23. 오전 10:10...
  • Page 28: Wiring Diagram

    5. Wiring Diagram DWM30-999PG DWM30-999PG(영_SM).indd 27 16. 8. 23. 오전 10:10...
  • Page 29: Part List And Major Specifications

    HARNESS EARTH 3612794420 D-M301 Daesh 66126-0014704-01 361279C000 FULL OPTION DONG-YANG DWD-M301 Dongya CLAMP CORE EMI SUB HARNESS 361279A621 D-M301,TR29 X 19 X 15 G5B 8TURN, Dongyou FUSE SWITCH DOOR LOCK 3619047230 DL-S2 ,BITRON, VE-TYPE DWM30-999PG(영_SM).indd 28 16. 8. 23. 오전 10:10...
  • Page 30 1st: d.c. 310V, 2nd: d.c. 12V, 15 V, Class E ◎ ◎ TUBE nTeko ◎ ◎ ◎ ◎ Daeshin Electronics ◎ ◎ -M301 Dongyang Electronics ◎ ◎ Dongyoung Electronics ◎ ◎ Vitron ◎ ◎ DWM30-999PG(영_SM).indd 29 16. 8. 23. 오전 10:10...
  • Page 31 It doesn't require recharges even after repetitive uses. 4 SENSOR ASS' Y It provides power to the coil of stator. It contains the hall IC to enable the assessment of motor speed. DWM30-999PG(영_SM).indd 30 16. 8. 23. 오전 10:10...
  • Page 32 [Disassembly] 1 Separate the power supply device and hall sensor connector from the motor 2 Separate the belt 3 Disconnect 4 motor-fixing bolts [Assembly] Re-assemble the parts in the opposite sequence to disassembly DWM30-999PG(영_SM).indd 31 16. 8. 23. 오전 10:10...
  • Page 33 180 degrees to start drainage. After drainage is complete, the power supply is reconnected from PCB to maintain the operation for a while and turn off the connection, which leads to close the bellows. DWM30-999PG(영_SM).indd 32 16. 8. 23. 오전 10:10...
  • Page 34 Cap Filter Drain Assembly * Examine the operation of drain motor * Exchange the drain motor * Examine the motor coil resistance * Take corrective measures after inspecting relevant parts (water supply valve, pcb triac, etc.) DWM30-999PG(영_SM).indd 33 16. 8. 23. 오전 10:10...
  • Page 35 1 Push the stopper of housing and turn the motor base counterclockwise to detach the bellows. 2 Examine the inside to remove any impurities. 3 Exchange only the motor if the motor causes poor operation. [Assembly] Re-assemble the parts in the opposite sequence to disassembly. DWM30-999PG(영_SM).indd 34 16. 8. 23. 오전 10:10...
  • Page 36 If the power supply is cut off, the coil's magnetic field disappears and the force of internal spring leads the rod valve to close the diaphragm hall, leading to block the water flow. DWM30-999PG(영_SM).indd 35 16. 8. 23. 오전 10:10...
  • Page 37: Dwm30-999Pg(영_Sm).Indd

    2. Examine the drainage drainage housing • Impurities • Remove impurities Housing) through the drainage hose • Error in returns • Exchange the 3. Check any impurities in of synchronous synchronous motor valve housing motor DWM30-999PG(영_SM).indd 36 16. 8. 23. 오전 10:10...
  • Page 38 1 Connect the inlet hose properly to the inlet (red) and outlet (gray) 2 Fasten the screw properly to prevent abrasion 3 Insert the inlet hose into valve tightly [Assembly of Inlet Valve] DWM30-999PG(영_SM).indd 37 16. 8. 23. 오전 10:10...
  • Page 39 The heater Thermister Included in heater temperature is set at around 270°C. Materials AISI321 • The water heater must be used in water. Max. Temperature WATER Part Code 3612804000 Water Heater Water Temperature Sensor DWM30-999PG(영_SM).indd 38 16. 8. 23. 오전 10:10...
  • Page 40 5. "H8": Overheated water heater (The water temperature rises by 6°C or more within 30 seconds after the heater starts running due to the lack of water in tub) DWM30-999PG(영_SM).indd 39 16. 8. 23. 오전 10:10...
  • Page 41 After the wash cycle is complete at the preset level and the water is drained, the head pressure declines to return the metal core to the original condition, enabling the repetitive application of function during the cycle. DWM30-999PG(영_SM).indd 40 16. 8. 23. 오전 10:10...
  • Page 42 • The reset level is immeasurable. • Defective PCB • Defect in pressure sensor (Defective oscillating condenser) • The water level is wrongly measured. • Impurities in air trip inlet • Defective PCB DWM30-999PG(영_SM).indd 41 16. 8. 23. 오전 10:10...
  • Page 43 6. Specifications, Operation, and Defect Inspection of Door Lock Switch 1) Specifications of Door Lock Switch TYPE Part Code Model Power Locking Mechanism DWM30-999PG 36169047230 DWM30-999PG 250V 16A Bimetal operation on the PTC heat Lock "On/Off" Time Lock Off Type Configuration 1.
  • Page 44 6. Remove 2 screws fixing the door lock switch 7. Detach the door lock switch and F-PCB connector 2 3 4 5 (No.1 wire unavailable) [Assembly] Re-assemble the parts in the opposite sequence to disassembly . DWM30-999PG(영_SM).indd 43 16. 8. 23. 오전 10:10...
  • Page 45 2) Specifications and Major Test Items - Size of conductor: 1.5mm2 - Thickness of sheath: 0.8mm - Thickness of insulator: 0.6mm - External diameter of insulator: 8.4±1mm 3) Assembly - Before fastening - After fastening DWM30-999PG(영_SM).indd 44 16. 8. 23. 오전 10:10...
  • Page 46: Installation

    * Fix the grounding wire with grounding screws. * Insert the inlet/drain hoses into the back holes * Do not ground multiple grounding wires in a single after connection. place. DWM30-999PG(영_SM).indd 45 16. 8. 23. 오전 10:10...
  • Page 47 3 Branch off the inlet hose * Install Install fiter inlet near the water supply valve * Examine whether a water leak occurs after instillation. * Examine whether a water leak occurs after instillation. DWM30-999PG(영_SM).indd 46 16. 8. 23. 오전 10:10...
  • Page 48 If a power cord is broken, you should contact the sales store Exchange of Power Cord or service center as a special tool is required. Contact the service center to relocate the installation. Relocation (Additional charge applies) DWM30-999PG(영_SM).indd 47 16. 8. 23. 오전 10:10...
  • Page 49 DWM30-999PG(영_SM).indd 48 16. 8. 23. 오전 10:10...
  • Page 50 서울 종로구 통의동 6 번지 이룸빌딩 4 층 담 당 김현규 님 M O D E L DWM30-999PG (영문 _ Service Manual) 접 수 2016.08.23 M E M O 총 49p (186 x 259) 16.08.23-표지, 1p, 3p, 4p, 8p, 9p, 10p, 11p, 13p, 14p, 15p, 16p, 18p, 19p, 21p, 27p,...