Technical Data - Shure Conference Phone User Manual

Shure conference phone user manual
Hide thumbs Also See for Conference Phone:
Table of Contents

Advertisement

8 Technical Data

Power supply unit C1-PS 60i
Mains voltage
C1-PS 60i A:
C1-PS 60i J:
C1-PS 60i E, C1-PS 60i UK :
Power rating:
Primary Fuses
C1-PS 60i A:
C1-PS 60i J:
C1-PS 60i E, C1-PS 60i UK :
Secondary Fuses:
Bus supply voltage:
Microphone
Audio inputs
(balanced)
Impendance
Input Clipping
Level
Phantom
Power
Audio outputs
Impendance
Output Clipping Level
Headphone Output
Output impedance:
Socket:
Connections:
Maximum number of consoles
per console-bus branch (Minicon):
per Sub-D 25 output:
Maximum total number of consoles:
Maximum length of a console-bus branch:
Maximum cable length from PSU to last console:
17
Line
(balanced)
8 kOhm
8 kOhm
-26 dBV
+6 dBV
15 V DC
--
Line
(balanced)
<20 Ohm
+18 dBV
120 V AC, 50/60 Hz
100 V AC, 50/60 Hz
220 - 240 V AC, 50/60 Hz
330 VA
T4A
T5A
T2A
2 x T8A
+/- 24 V DC nom.
Aux
(unbalanced)
50 kOhm
+6 dBV
--
Aux
(unbalanced)
<20 Ohm
+12 dBV
8 Ohm
1/4" stereo jack socket
15
30
60
40 m
80 m
English
AEC / Telco
Audio Interface
(balanced)
50 kOhm
+20 dBV
--
AEC / Telco
Audio Interface
(balanced)
200 Ohm
+18 dBV

Advertisement