Sharp PN-455 Operation Manual page 51

Sharp pn-455 lcd monitor operation manual
Table of Contents

Advertisement

Special Control
Control item
OFF TIMER
ID NO.
SETTING
ID NO.
SETTING
(ONCE)
ID NUMBER
ID NO.
SETTING
(SUBSEQUENT)
ID CHECK
MODEL
Information
SERIAL NO.
Display mode
Brightness
Volume
Mute
ALL RESET
ADJUSTMENT
OSD DISPLAY
LED OFF
CAUSE OF LAST STANBY
Temperature
Status check
Fan
Command Direction
Parameter
0
W
1-23
OFTM
R
W
0-255
IDST
R
1-255
IDSL
W
0
1-255
IDLK
W
0
IDCK
W
0
INF1
R
SRNO
R
0
BMOD
WR
1
2
VLMP
WR
0-max value
VOLM
WR
0-max value
0
MUTE
WR
1
RSET
W
0
0
ALCK
WR
1
0
LOSD
WR
1
0
OFLD
WR
1
W
0
STCA
R
ERRT
R
ERRF
R
Reply
Control/Response contents
TIMER OFF
OFF TIMER
0
TIMER OFF
1-23
Remaining time
Sets the monitor's ID number.
0-255
Returns the monitor's ID number.
Sets a monitor ID number. This ID number is only
effective for the command immediately after this
command.
Clears the ID number if one has been designated.
Sets a monitor ID number. This ID number is
effective for the next and all subsequent commands
after this command.
Clears the ID number if one has been designated.
Displays selected ID number and the monitor's own
ID number on the screen.
Value
Value
STANDARD
0
OFFICE MODE
1
2
VIVID MODE
0-max value
BRIGHTNESS
0-max value
0
OFF
1
ON
ALL RESET
0
OSD DISPLAY ON
1
OSD DISPLAY OFF
0
ADJUSTMENT UNLOCKED
1
ADJUSTMENT LOCKED
0
LED ON
1
LED OFF
Initialization
0
No detectable error has occurred
1
Standby by remote control
2
Standby by power switch
3
Standby by RS-232C
4
Waiting by No Signal/Out of Timing (Incl: VESA DPMS/DMPM)
5
Standby by FAN error
6
Standby by abnormal temperature
Value
Temperature
0
No error
1
FAN error
*can be used in standby mode
*
No
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
No
Yes
Yes
Yes
Yes
No
51
E

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pn-455pPn-455rupPn-455 - 45" lcd flat panel display

Table of Contents