Channel-Specific Signals; Signals To Channel - Siemens SINUMERIK 808D ADVANCED Operating Instructions Manual

Parameter manual
Hide thumbs Also See for SINUMERIK 808D ADVANCED:
Table of Contents

Advertisement

DB3100
DBX0.3
Edge evaluation: No
Signal state 1 or edge
change 0 → 1
Signal state 0 or edge
change 1 → 0
Special cases, errors,
...
Note for the reader
DB3100
DBX1.2
Edge evaluation: No
Signal state 1 or edge
change 0 → 1
Signal state 0 or edge
change 1 → 0
Note for the reader
4.7

Channel-specific signals

4.7.1

Signals to channel

DB3200
DBX0.3
Edge evaluation: No
Signal state 1 or edge
change 0 → 1
Siemens Controls
Parameter Manual
Operating Instructions, 08/2013, 6FC5397-8EP40-0BA0
808D READY
Signal(s) from NCK (NCK → PLC)
Signal(s) updated: Cyclic
This signal is set after power on and all of the voltage have been established.
The mode group is now ready and part programs can be executed and axes
traversed.
The mode group/channel is not ready. Possible causes for this are:
There is a critical axis or spindle alarm present
Hardware fault
Mode group incorrectly configured (machine data)
If the mode group ready changes to signal state "0", then
the axis and spindle drives are braked down to standstill with the max.
braking current.
the signals from the PLC to the NCK are brought into an inactive state
(initial setting).
An alarm that withdraws IS "808D READY" ensures that the channel is no
longer in the reset state. A reset is required to switch over to another mode.
(DB3000 DBX0.7)
Function Manual Basic Functions K1
Active machine function REF
Signal(s) from NCK (NCK → PLC)
Signal(s) updated: Cyclic
Machine function REF is active within JOG.
Machine function REF is not active.
Function Manual Basic Functions K1
Activate DRF
Signal(s) to channel (PLC → NCK)
Signal(s) updated: Cyclic
The function DRF is selected.
The function can either be selected directly from the PLC user program or
from the operator panel front via HMI interface signal:
DB1700 DBX0.3 (DRF selected)
As soon as the function DRF is active, DRF offset can be modified in the
AUTOMATIC or MDI modes.
Detailed descriptions of interface signals
4.7 Channel-specific signals
349