Loop Rate - Sw 4; Clear To Send (Cs) - Sw 5; Table 2-A Switch Settings For Dte Async Rate - ADTRAN DSU 5600 User Manual

Data service unit
Table of Contents

Advertisement

Loop Rate - SW 4

Clear To Send (CS) - SW 5

61200.078L1-1
DTE Rate
1.2 and 2.4 kbps Async
Sync, Scrambler Disabled
4.8 kbps Async
9.6 kbps Async
19.2 kbps Async
38.4 kbps Async
57.6 kbps Async
Sync, Scrambler Enabled
When the SW4 switch is in the down (56 kbps) position, the
network interface of the DSU 5600 is configured for operation at
56 kbps, and when this switch is in the up (64 kbps) position, the
network interface is configured for 64 kbps operation.
For 64 kbps clear channel operation, there is a possibility that the
DTE data sequences might mimic network loop maintenance
functions and erroneously cause other network elements to
activate loopbacks. To prevent this, a data scrambler is enabled
when the 64 kbps option is selected.
When this switch is in the down (normal) position Clear To Send
(CS) follows the Request To Send (RS) lead with 250 µ ± 125 µ of
delay. The only exceptions to this occur when network or test
conditions prevent data from being transferred over the DTE
interface. During these conditions CS is turned Off.
For the up (On) position CS is forced On all the time.
DSU 5600 User Manual
Chapter 2. Installation
Switch Settings for DTE Rate
SW 1
SW 2
Down
Down
Up
Down
Down
Up
Up
Up
Down
Down
Up
Down
Down
Up
Up
Up
Table 2-A
SW 3
Down
Down
Down
Down
Up
Up
Up
Up
9