1.0 IMPORTANT SAFETY AND OPERATING INSTRUCTIONS This manual contains important safety and operating instructions for standard Curtis chargers. Please read this information in its entirety before using your Charger. WARNING Use charger only with an algorithm selected that is appropriate to the specific battery type. Other usage may cause personal injury and damage.
When battery is not connected: Charge Profile (Algorithm Number) display. Amber If flashing: Reduced power mode. Low AC voltage or high internal charger temperature. If flashing: Charging error. Reset charger power and refer to Troubleshooting Instructions below. Curtis Model 1624 Manual...
This charger is provided with a cord set for connection to outlets operating at nominal 120 Volts (or 240 Volts as appropriate). If the input plug does not fit the power outlet, contact Curtis Instruments for the proper cord set terminating in an attachment plug of the proper configuration for the power outlet.
WARNING: Charger connectors must be mated to connectors from the same manufacturer. Failure to do so may void warranty and cause a hazardous condition or equipment damage. Curtis Model 1624 Manual...
4.0 SELECTING A CHARGE PROFILE The 1624 Charger can store up to 10 charging profiles, also called charge algorithms. This section shows how to identify the default profile and select a new profile using the “tap method.” Model 1624 chargers are also reprogrammable by using the dedicated programmer. Pre-2006 Model 1624 chargers with serial number prefix DQCP allow pre-loaded profiles to be selected but cannot be reprogrammed with new profiles.
Page 8
13. Disconnect the charger from AC power and wait for the Figure 8: Reattach the positive lead to the LED indicator display to turn off. (Figure 1) positive terminal after disconnecting AC power. 14. Reconnect the positive lead to the positive battery terminal (Figure 8). Curtis Model 1624 Manual...