Download Print this page

Samsung SGH-E350 Service Manual page 52

Gsm telephone
Hide thumbs Also See for SGH-E350:

Advertisement

Flow Chart of Troubleshooting
12. GSM Receiver
RF input : CH center freq : +67.7kHz
pin E1 >= -70dBm
pin F1 >= -70dBm
Downloaded from
www.Manualslib.com
RX ON
Amp : -50dBm
Yes
MODULE1 Pin7
>= -65dBm
Yes
U100 pin1,2
>= -68dBm
Yes
U100
Yes
U100 pin
H8,J8,H7,J7
>= 1V
Yes
Check U200
END
SAMSUNG Proprietary-Contents may change without notice
This Document can not be used without Samsung's authorization
manuals search engine
No
Resolder CN100, C102
No
Check MODULE1
pin9,pin10,pin12 = L
No
Resolder C105, C114, L105
No
R110, C126, C129
>=2.7V
Yes
7-24
No
Check ANT Switch
control circuit
Yes
Resolder MODULE1
No
Check & Resolder
RF26MHz, RF PSU Part
Resolder U100
U100, R113

Advertisement

loading