Technical Specifications - Graco EcoQuip EQ200T Operation, Repair, And Parts

Vapor abrasive blast system
Hide thumbs Also See for EcoQuip EQ200T:
Table of Contents

Advertisement

Technical Specifications

Technical Specifications
Specifications
Technical
Technical
Specifications
EQ200T
EQ200T
EQ200T
Maximum Working Pressure
Operating Temperature
Air Consumption
Blast Hose Size
Abrasive Capacity
GVWR
Pressure Pot Volume
Water Tank Volume
Sound Data*
Data*
Sound
Sound
Data*
Sound Pressure Level
Sound Power Level
Instantaneous Sound Pressure Level
*All readings were taken at the maximum system blast pressure 125 psi (8.6 bar, 0.86 MPa) from the operator
position. The abrasive used was garnet and the substrate was steel. Tested in accordance with ISO 9614–2.
EQ400T
EQ400T
EQ400T
Maximum Working Pressure
Operating Temperature
Air Consumption
Blast Hose Size
Abrasive Capacity
GVWR
Pressure Pot Volume
Water Tank Volume
Sound Data*
Sound
Sound
Data*
Data*
Sound Pressure Level
Sound Power Level
Instantaneous Sound Pressure Level
*All readings were taken at the maximum system blast pressure 125 psi (8.6 bar, 0.86 MPa) from the operator
position. The abrasive used was garnet and the substrate was steel. Tested in accordance with ISO 9614–2.
48
U.S.
U.S.
U.S.
125 psi
35° – 110° F
165 – 375 cfm
1 in. ID
400 – 500 lb
6160 lb
6.5 cubic feet
100 gallon
133 dB(A)
139 dB(A)
131 dB(C)
U.S.
U.S.
U.S.
125 psi
35° – 110° F
375 – 600 cfm
1.25 in. ID
400 – 500 lb
11000 lb
6.5 cubic feet
130 gallon
133 dB(A)
139 dB(A)
131 dB(C)
Metric
Metric
Metric
8.6 bar, 0.86 MPa
1.6° – 43.3° C
4.67–10.62 m^3/min
25.4 mm ID
181 – 227 kg
2794 kg
184 liters
378 liters
133 dB(A)
139 dB(A)
131 dB(C)
Metric
Metric
Metric
8.6 bar, 0.86 MPa
1.6° – 43.3° C
10.62–17.0 m^3/min
31.75 mm ID
181 – 227 kg
4990 kg
184 liters
492 liters
133 dB(A)
139 dB(A)
131 dB(C)
334666B

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ecoquip eq400tEcoquip seriesEq300cEq600c

Table of Contents