Broan 112 Instructions Manual

Broan 112 Instructions Manual

Kickspace heater. factory wired 240/208 v.a.c.
Hide thumbs Also See for 112:
Table of Contents

Advertisement

Available languages

Available languages

KICKSPACE HEATER
Factory Wired 240/208 V.A.C.
READ AND SAVE THESE INSTRUCTIONS

IMPORTANT INSTRUCTIONS

READ ALL INSTRUCTIONS BEFORE
INSTALLING OR USING THIS HEATER.
To reduce the risk of fire, electric shock, or injury to persons,
observe the following:
1. Use this unit only in the manner intended by the manufacturer.
If you have questions, contact the manufacturer at the address
or telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service
panel and lock the service disconnecting means to prevent
power from being switched on accidentally. When the service
disconnecting means cannot be locked, securely fasten a
prominent warning device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by a
qualified person(s) in accordance with all applicable codes
and standards, including fire‑rated construction codes and
standards.
4. When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities.
5. This heater is hot when in use. To avoid burns, do not let bare
skin touch hot surfaces. Keep combustible materials, such as
furniture, pillows, bedding, papers, clothes, etc. and curtains at
least 3 feet (0.9 m) from the front of the heater.
6. Extreme caution is necessary when any heater is used by
or near children or invalids and whenever the heater is left
operating and unattended.
7. Do not operate any heater after it malfunctions. Disconnect
power at service panel and have heater inspected by a
reputable electrician before reusing.
8. Do not use outdoors.
9. To disconnect heater, turn controls to off, and turn off power
to heater circuit at main disconnect panel (or operate internal
disconnect switch, if provided).
10. Do not insert or allow foreign objects to enter any ventilation or
exhaust opening, as this may cause an electric shock or fire, or
damage the heater.
11. To prevent a possible fire, do not block air intakes or exhaust in
any manner.
12. A heater has hot and arcing or sparking parts inside. Do not
use it in areas where gasoline, paint, or flammable vapors or
liquids are used or stored.
13. Use this heater only as described in this manual. Any other use
not recommended by the manufacturer may cause fire, electric
shock, or injury to persons.
14. To avoid electrical shock: Do not install unit in a tub or shower
enclosure or any location where it may come in contact with
water. Never place a switch where it can be reached from a tub
or shower.
15. Do not connect heater to dimmer switch or speed control.
16. Do not install heater upside down or sideways. Heater must be
located in the horizontal position.
17. Do not recess louvered face of the heater more than three inches
from the vertical face of any overhang (cabinet).
18. Provide this heater with a separate electrical circuit following
directions under "Wiring" section.
19. This product is equipped with a thermostat which may start it
automatically. Turn off power at service entrance before cleaning
or servicing.
20. This heater includes a visual alarm to warn that parts are getting
excessively hot. If the alarm lights are activated, immediately
turn the heater off and inspect for any objects on or adjacent
to the heater that may cause high temperatures.
21. This product must be grounded.
SAVE THESE INSTRUCTIONS
PLANNING
This heater is designed for installation in an enclosed space such
as under a counter or kickspace to provide warm, gentle heat at
the floor level. Reread Safety Notes 3 through 8 for guidelines in
planning the installation.
The Model 112 is factory wired for 240/208 V.A.C. operation. It offers
a choice of heat outputs and can be internally connected for multiple
wattages at different voltages shown in the table below.
VOLTS
WATTS
240
1500
208
1125
120*
1500
120*
750
All ratings are 1‑Phase, 60 Hertz.
*See "FIELD CONVERSION TO 120 V.A.C." section.
Cutout dimension: 18‑3/8" x 3‑5/8"
MODEL 112
Page 1
AMPS
BTU/HR
6.3
5120
5.4
3840
12.5
5120
6.3
2560

Advertisement

Table of Contents
loading

Summary of Contents for Broan 112

  • Page 1: Important Instructions

    4. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities. The Model 112 is factory wired for 240/208 V.A.C. operation. It offers 5. This heater is hot when in use. To avoid burns, do not let bare a choice of heat outputs and can be internally connected for multiple skin touch hot surfaces.
  • Page 2: Installation

    MODEL 112 Page 2 INSTALLATION WARNING: To reduce the risk of fire, do not store or use gaso- 3. Remove alarm light wire leads from terminals “1” and “3” of line or other flammable vapors and liquids in the vicinity of the high temperature limit.
  • Page 3: Operation

    MODEL 112 Page 3 OPERATION Before using heater, make sure heater has been properly installed according to installation steps beginning with the “PLANNING” section on page 1. Turn thermostat counterclockwise to its lowest setting. 2. Turn on power to circuit at service entrance.
  • Page 4: Maintenance

    MODEL 112 Page 4 MAINTENANCE The following maintenance and cleaning tasks can be performed by the user. All other servicing must be performed by an authorized technician If you have any questions, please consult with our cus‑ tomer service department at: 800‑558‑1711.
  • Page 5: Warranty

    Limited Warranty Warranty Period and Exclusions: Broan‑NuTone LLC (the “Company”) warrants to the original consumer purchaser of its product (“you”) that the product (the “Product”) will be free from material defects in the Product or its workmanship for a period of one (1) year from the date of original purchase.
  • Page 6: Service Parts

    MODEL 112 Page 6 SERVICE PARTS SERVICE PARTS PART NUMBER PART DESCRIPTION 99522899 Cover (White) 99522400 Cycling Thermal Overload Limit Switch 99521763 Thermal Fuse 99521765 Motor 99020130 Blower Wheel 99521760 Motor Plate 99521761 Element Retainer 99271288 Heater Element (2 Required)
  • Page 7: Instrucciones Importantes

    El MODELO 112 está cableado de fábrica para funcionamiento con 6. Es necesario tener extremo cuidado cuando se use un calentador 240/208 VCA. Ofrece una selección de salidas de calor y puede cerca de niños o personas inválidas, y siempre que el calentador se...
  • Page 8: Instalación

    MODELO 112 Pagína 8 INSTALACIÓN terminal límite “1” y conéctelo a la terminal límite “3” . Para evitar ADVERTENCIA: Para reducir el riesgo de incendio, no almacene ni interferencias en el funcionamiento de la unidad, amarre los use gasolina u otros vapores y líquidos flamables en las cercanías cables con atadura de cables.
  • Page 9 MODELO 112 Pagína 9 FUNCIONAMIENTO Antes de usar el calentador, asegúrese de que esté instalado adec‑ uadamente, de acuerdo con los pasos de instalación indicados en “PLANIFICACIÓN” en la página 5. Gire el termostato en el sentido contrario de las agujas del reloj hasta su ajuste más bajo.
  • Page 10: Mantenimiento

    MODEL 112 Page 10 MANTENIMIENTO El usuario puede realizar las siguientes tareas de mantenimiento y limpieza. Todos los demás servicios los debe realizar un técnico autorizado. Si tiene preguntas, consulte a nuestro departamento de servicio al cliente llamando al: 800‑558‑1711.
  • Page 11 Garantía limitada Periodo y exclusiones de la garantía: Broan‑NuTone LLC (la “Compañía”) garantiza al consumidor comprador original de su producto (“usted”) que el producto (el “Producto”) estará libre de defectos en materiales o en mano de obra, por un periodo de un (1) año a partir de la fecha de compra original.
  • Page 12: Piezas De Repuesto

    MODELO 112 Pagína 12 PIEZAS DE REPUESTO PIEZAS DE REPUESTO CLAVE NÚMERO DE PIEZA DESCRIPCIÓN DE LA PIEZA 99522899 Cubierta (blanca) 99522400 Interruptor limitador de sobrecarga térmica (cíclico) 99521763 Fusible térmico 99521765 Motor 99020130 Rueda del soplador 99521760 Placa del motor...

Table of Contents