Unit Size
Nominal Capacity --- ton
Shipping Weight (lb)
(kg)
Compressor / Quantity
Refrigerant
Refrigerant Quantity (lb)
Quantity (kg)
Refrigerant Metering Device
Orifice ID (in)
(mm)
Orifice OD (in)
(mm)
Outdoor Coil
Rows... Fins/in,
face area (sq. ft.)
Outdoor Fan
Nominal Airflow (cfm)
Diameter (in.)
Diameter (mm)
Motor hp
Motor (rpm)
Indoor Coil
Rows... Fins/in,
face area (sq. ft.)
Indoor Blower
Nominal Airflow (cfm)
Size (in.)
Size (mm)
Motor hp
Furnace Section*
Burner Orifice
1 Phase Natural Gas Qty...Drill Size
1 Phase Propane Gas Qty...Drill Size
3 Phase Natural Gas Qty...Drill Size
3 Phase Propane Gas Qty...Drill Size
High Pressure Switch (psig)
Cutout
Reset (Auto)
Loss--- of--- Charge/Low Pressure
Switch (psig)
Cutout
Reset (Auto)
Return Air Filters{}
disposable
*Based on altitude of 0 to 2000 ft (0 ---610 m).
{Required filter sizes shown are based on the larger of the AHRI (Air Conditioning Heating and Refrigeration Institute) rated cooling airflow or the heating airflow
velocity of 300 to350 ft/minute for high ---capacity type. Air filter pressure drop for non ---standard filters must not exceed 0.08 IN. W.C.
} If using accessory filter rack refer to filter rack installation instructions for correct filter size and quantity.
NOMINAL
INTERNAL
IRON
DIAMETER
10
PIPE, SIZE
(IN.)
(3.0)
(IN.)
1/2
.622
175
3/4
.824
360
1
1.049
680
1 ---1/4
1.380
1400
1 ---1/2
1.610
2100
* Capacity of pipe in cu ft of gas per hr for gas pressure of 0.5 psig or less. Pressure drop of 0.5--IN. W.C. (based on a 0.60 specific gravity gas). Refer to Table 2
and the NFGC NFPA 54/ANSI Z 223.1.
† This length includes an ordinary number of fittings.
HEATING INPUT
NUMBER OF
NUMBER OF
(BTUH)
ORIFICES
ORIFICES
40,000
2
60,000
3
90,000
3
115,000
3
130,000
3
*When a unit is converted to propane, different size orifices must be used. See separate, natural ---to ---propane conversion kit instructions.
Based on altitudes from sea level to 2000 ft (610 m) above sea level. In th e U.S.A. for altitudes above 2000 ft (610 m), reduce input rating 4 percent for each
{
additional 1000 ft (305 m) above sea level. In Canada, from 2000 ft (610 m) above sea level to 4500 ft (1372 m) above sea level, derate the unit 10 percent.
51801230403
Table 1 - - Physical Data Cont'd)
42060
42090
48090
3.5
3.5
4
475
475
500
215
215
227
11.2
11.2
9.9
5.1
5.1
4.5
Indoor TXV,
Outdoor Dual
Accuraters
N/A
0.046 (2)
0.046 (2)
0.046 (2)
1.17 (2)
1.17 (2)
1.17 (2)
1...21
1...21
1...21
23.3
23.3
23.3
3500
3500
3500
26
26
26
660
660
660
1/5
1/5
1/5
(810)
(810)
(810)
3...17
3...17
3...17
4.7
4.7
4.7
1350
1350
1600
11 x 10
11 x 10
11 x 10
279 x 254
279 x 254
279 x 254
1/2
1/2
1
3...44
3...38
3...38
3...55
3...53
3...53
2...38
3...38
3...38
2...53
3...53
3...53
1 each 24x14x1 (610x356x25)
24x15x1 (610x406x25)
Table 2 – Maximum Gas Flow Capacity*
20
30
40
50
(6.1)
(9.1)
(12.2)
(15.2)
120
97
82
73
250
200
170
151
465
375
320
285
950
770
600
580
1460
1180
990
900
Table 3 – Heating Inputs
GAS SUPPLY PRESSURE (IN. W.C.)
Natural{
Min
Max
4.0
13.0
4.0
13.0
4.5
13.0
4.5
13.0
4.5
13.0
Specifications are subject to change without notice.
48115
48130
4
4
500
500
227
227
Scroll / 1
R --- 410A
9.9
9.9
4.5
4.5
Indoor Accurater,
Outdoor Dual Accuraters
0.080 (1)
2.03 (1)
0.046 (2)
0.046 (2)
1.17 (2)
1.17 (2)
1...21
1...21
23.3
23.3
3500
3500
26
26
660
660
1/5
1/5
(810)
(810)
3...17
3...17
4.7
4.7
1600
1600
11 x 10
11 x 10
279 x 254
279 x 254
1
1
3...33
3...31
3...51
3...49
3...33
3...31
3...51
3...49
650 +/--- 15
420 +/--- 25
20 +/--- 5
45 +/--- 10
LENGTH OF PIPE, FT (m)†
60
70
80
90
(18.3)
(21.3)
(24.4)
(27.4)
66
61
57
53
138
125
118
110
260
240
220
205
530
490
460
430
810
750
690
650
Propane*{
Min
Max
11.0
13.0
11.0
13.0
11.0
13.0
11.0
13.0
11.0
13.0
60090
60115
60130
5
5
515
515
515
234
234
234
11.9
11.9
11.9
5.4
5.4
5.4
Indoor TXV,
Outdoor Dual Accuraters
N/A
0.052 (2)
0.052 (2)
0.052 (2)
1.32 (2)
1.32 (2)
1.32 (2)
2...21
2...21
2...21
17.5
17.5
17.5
3500
3500
3500
26
26
26
660
660
660
1/4
1/4
1/4
(810)
(810)
(810)
3...17
3...17
3...17
5.6
5.6
5.6
1750
1750
1750
11 x 10
11 x 10
11 x 10
279 x 254
279 x 254
279 x 254
1
1
3...38
3...33
3...31
3...53
3...51
3...49
3...38
3...33
3...31
3...53
3...51
3...49
1 each 24x16x1 (610x406x25)
24x18x1 (610x457x25)
100
125
150
175
(30.5)
(31.1)
(45.7)
(53.3)
50
44
40
103
93
84
77
195
175
160
145
400
360
325
300
620
550
500
460
MANIFOLD PRESSURE
MANIFOLD PRESSURE
(IN. W.C.)
Natural{
Propane*†
3.23.8
10.0
3.23.8
10.0
3.23.8
10.0
3.23.8
10.0
3.23.8
10.0
11
5
1
200
(61.0)
72
135
280
430

Hide quick links: