Installation Information - Panasonic CU-3TZ52TBE Service Manual

Outdoor unit
Table of Contents

Advertisement

10. Installation Information

10.1.1
Check Points
Outdoor unit power supply:
Single-phase 230V, 50Hz
16A switch
(circuit breaker)
(Not included in the unit)
2
2.5 mm
or more x 3 core
(Not included in the unit)
Outdoor
wiring work
Indoor/outdoor unit
connection cables
(Not included in the unit)
1.5 mm
Unit C
(polychloroprene sheathed)
(Not included in the unit)
Unit B
2
1.5 mm
flexible cord x 4 core
(polychloroprene sheathed)
(Not included in the unit)
Unit A
Applicable connecting tube kit:
CZ-3F type
Unit A Maximum pipe length: 25 m
Unit B Maximum pipe length: 25 m
Unit C Maximum pipe length: 25 m
Total maximum pipe length: 50m
Grounding work
24
2
flexible cord x 4 core
.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents