Transmission Rate Setting, Line Test, Hardware Test, Transmission Speed Test - Mitsubishi FX3U User Manual

Melsec-f, cc-link v2
Hide thumbs Also See for FX3U:
Table of Contents

Advertisement

FX
-16CCL-M User's Manual
3U
3) Duplicate station numbers are not allowed.
If there are duplicate numbers, a loading status error occurs.
The error code is stored in SW0069 (BFM#1641).
- When one station number is duplicated
Station No. 0
Station
No. 0
Master
station
(fixed)
9.3.2

Transmission rate setting, line test, hardware test, transmission speed test

Set the transmission rate setting, line test, hardware test and transmission speed test using the transmission
rate setting switch (Setting range: 0 to E).
For details on the transmission rate setting, line test, hardware test, transmission speed test, refer to the
following.
Setting
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
Caution
• Set the same transmission speed to the master station and remote stations/intelligent device stations. If
the setting is different in even one station, normal data link is not possible.
• The maximum transmission and distance cable length between stations that can be set varies depending
on the transmission speed.
For details, refer to Section 2.5.
90
Station No. 1
1)Remote I/O
Master
station
station
(occupies 1
station)
Station
Station
Station
No. 1
No. 2
No. 3
1)
2)
Remote
Remote
Remote device station
I/O
I/O
station
station
→ For details on the transmission speed test, refer to Section 9.5.
Transmission rate setting
Transmission rate 156 Kbps
Transmission rate 625 Kbps
Transmission rate 2.5 Mbps
Transmission rate 5 Mbps
Transmission rate 10 Mbps
Transmission rate 156 Kbps
Transmission rate 625 Kbps
Transmission rate 2.5 Mbps
Transmission rate 5 Mbps
Transmission rate 10 Mbps
Transmission rate 156 Kbps
Transmission rate 625 Kbps
Transmission rate 2.5 Mbps
Transmission rate 5 Mbps
Transmission rate 10 Mbps
Unusable
Station No. 2
Station No. 3
2)Remote I/O
station
(occupies 1
station)
Station
Station
Station
No. 4
No. 5
No. 6
3)
4)
Remote device station
→ For details on the line test, refer to Section 9.4.
→ For details on the hardware test, refer to Section 9.2.
Online
Transmission speed test
Line test
When the station number setting switch is 0:
Line test 1
When the station number setting switch is 1 to 16:
Line test 2
Hardware test
Unusable
9 Data Link Procedure
Station No. 6
3)Remote
4)Remote
device
device
station
station
(occupies 4
(occupies 2
stations)
stations)
Duplicate
station No.
Station
Station
Station
No. 7
No. 8
No. 9
Mode
9.3 Switch setting

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fx3u-16ccl-m

Table of Contents