Menu: Operation Screen - Siemens SINAMICS S120 Operating Instructions Manual

Cabinet modules operator panel (option k08)
Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Control via the operator panel

4.3 Menu: Operation screen

4.3
Menu: Operation screen
Description
The operation screen displays the most important status variables for the drive unit:
In its as-delivered condition, it displays the operating status of the drive, the direction of
rotation, the time, as well as four drive variables (parameters) numerically and two in the
form of a bar display for continuous monitoring.
You can call up the operation screen in one of two ways:
1. After the power supply has been switched on and the system has ramped up.
2. By pressing the MENU key twice and then F5 "OK 
 "
Figure 4-2
Figure 4-3
If a fault occurs, the system automatically displays the fault screen (see section "Faults and
alarms").
In LOCAL control mode, you can choose to enter the setpoint numerically (F2: setpoint).
The "Define operation screen" menu can be selected directly using F3 "Change".
The individual parameters of the operation screen can be selected using F4 "Sel. par". The
corresponding parameter number of the short identifier is displayed using F1 "Help+" and a
description of the parameter can be called up.
38
Operation screen - example of a drive in vector control mode
Operation screen - example of infeed via a Basic Line Module
Cabinet Modules Operator Panel AOP30
Operating Instructions, 04/2014, A5E03263551A

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Aop30

Table of Contents