Service/special operation
Chimney sweep function
Off | On
Manual control
Off | On
Controller stop function
0: Off | 1: On
Controller stop setpoint
Forced heat draw DHW
0: Off | 1: On
Commissioning wizard
0: Off | 1: On
Telephone customer service
PStick storage pos
PStick Reg data set
PStick command
0: No operation | 1: Reading from stick | 2: Writing on stick
PStick progress
PStick status
0: No stick | 1: Stick ready | 2: Writing on stick | 3: Reading from stick | 4: EMC
test active | 5: Writing error | 6: Reading error | 7: Incompatible data set | 8:
Wrong stick type | 9: Stick format error | 10: Check data set | 11: Data set
disabled | 12: Reading disabled
Config extension module
Function extension module 1
0: None | 1: Multifunctional | 2: Heating circuit 1 | 3: Heating circuit 2 | 4: Heating
circuit 3 | 6: Solar DHW | 7: Primary contr/system pump
Relay output QX21 module 1
0: None | 1: Circulating pump Q4 | 2: El imm heater DHW K6 | 3: Collector pump
Q5 | 4: Cons circuit pump VK1 Q15 | 5: Boiler pump Q1 | 7: Alarm output K10 |
11: Heat circuit pump HC3 Q20 | 12: Cons circuit pump VK2 Q18 | 13: System
pump Q14 | 14: Heat gen shutoff valve Y4 | 15: Solid fuel boiler pump Q10 | 16:
Time program 5 K13 | 17: Buffer return valve Y15 | 18: Solar pump ext exch K9 |
19: Solar ctrl elem buffer K8 | 20: Solar ctrl elem swi pool K18 | 22: Swimming
pool pump Q19 | 25: Cascade pump Q25 | 26: St tank transfer pump Q11 | 27:
DHW mixing pump Q35 | 28: DHW interm circ pump Q33 | 29: Heat request K27
| 33: Heat circuit pump HC1 Q2 | 34: Heat circuit pump HC2 Q6 | 35: DHW ctrl
elem Q3 | 40: Status output K35 | 41: Status information K36 | 43: Fan
shutdown K38
Relay output QX22 module 1
See
Parameters see Relay output QX21 module 1 (prog. no.
7301)!
Relay output QX23 module 1
See
Parameters see Relay output QX21 module 1 (prog. no.
7301)!
Sensor input BX21 module 1
0: None | 1: DHW sensor B31 | 2: Collector sensor B6 | 4: DHW circulation
sensor B39 | 5: Buffer sensor B4 | 6: Buffer sensor B41 | 8: Common flow
sensor B10 | 9: Solid fuel boiler sensor B22 | 10: DHW charging sensor B36 |
11: Buffer sensor B42 | 12: Common return sensor B73 | 13: Cascade return
sensor B70 | 14: Swimming pool sensor B13 | 16: Solar flow sensor B63 | 17:
Solar return sensor B64
Sensor input BX22 module 1
See
Parameters see Sensor input BX21 module 1 (prog. no. 7307)!
7703301 - 01 - 16072018
Prog. no.
Level
Standard value
7130
Eu
Off
7140
Eu
Off
7143
E
0: Off
7145
E
100 %
7165
E
0: Off
7167
E
0: Off
7170
C
0
7250
E
0
7252
E
0: No operation
7253
E
0 %
0: No stick
Prog. no.
Level
Standard value
7300
C
3: Heating circuit 2
7301
C
0: None
7302
C
0: None
7303
C
0: None
7307
C
0: None
7308
C
0: None
9 Settings