SUB-FLOOR
WALL SLEEVE FRAMING DIMENSIONS
NOTE: UNITS APPROVED FOR 0" CLEARANCE TO COMBUSTIBLE CONSTUCTIONS TOP, SIDES, AND BOTTOM. FRONT AND REAR CLEARANCE
NOT APPLICABLE AS THERE CAN BE NO CONSTRUCTION COMBUSTIBLE OR NON-COMBUSTIBLE TO THE FRONT OR REAR OF THE OPENING.
FRONT
SURFACE OF FINISHED INTERIOR WALL
X" REPRESENTS EITHER THE
DIMENSION REQUIRED TO FLUSH
SLEEVE TO FINISHED TRIM OR
MOLDING, OR THE DISTANCE
SLEEVE PROJECTS INTO ROOM
BEYOND FINISHED INTERIOR
WALL.
NOTE: X" CAN BE 0" IF
SLEEVE IS FLUSH WITH
FINISHED INTERIOR WALL.
Suburban DynaLine Owner's Manual 10/2017 Rev.1
HEADER
(STEEL LINTEL IN BRICK CONSTRUCTION)
1"
42
MIN.
4
FINISHED FLOOR
FRONT GAS HOOK-UP
Figure 3
NOTCH FOR OPTIONAL
REAR GAS HOOKUP
BE SURE DRAIN
HOLES ARE TO
OUTSIDE
REAR
GASKET
CABINET FRONT
SURFACE OF FINISHED
FLOOR OR TOP OF CARPET
WALL INSTALLATION
REAR GAS HOOKUP
1"
16
MIN.
4
1"
3 2
MIN.
INSERT SIDES BETWEEN TOP FLANGE
AND RETAINING ANGLE
SLEEVE BOTTOM AND SIDES
Figure 4
3"
Y" = 14
- ( X" + 1
Y"
4
X"
SURFACE OF FINISHED EXTERIOR WALL
CAULK AROUND WALL SLEEVE
REAR GRILLE
MOUNTING HOLES AND SCREWS
(BY INSTALLER.)
DO NOT PUT HOLES THROUGH
WALL SLEEVE BOTTOM!
1"
SLOPE DOWN TO THE OUTSIDE
4
5"
1
MIN. (PROJECTION BEYOND EXTERIOR WALL)
8
Figure 5
8
BIRD GUARD
SCREW #8 X 1/2
Figure 4A
SLEEVE TOP
5"
)
8