Cheetah 10K.7 SCSI Installation Guide
ST3300007LW/LC/LCV, ST3146707LW/LC/LCV,
ST373207LW/LC/LCV
Publication Number: 100260917, Rev. A, March 2004
Handling precautions/Electrostatic discharge protection
• Disc drives are fragile. Do not drop or jar the drive. Handle the drive only
by the edges or frame.
• Drive electronics are extremely sensitive to static electricity. Keep the
drive in its antistatic container until you are ready to install it. Wear a wrist
strap and cable connected to ground. Discharge static from all items near
or that will contact the drive. Never use an ohmmeter on any circuit
boards.
• Turn off the power to the host system during installation.
• Always use forced-air ventilation when operating the drive.
• Use caution when troubleshooting a unit that has voltages present.
• Do not disassemble the drive; doing so voids the warranty.
• Return the entire drive for depot service if any part is defective.
• Do not apply pressure or attach labels to the drive.
Electromagnetic compliance
See Safety and Regulatory Agency Specifications, p/n 75789512.
Drive characteristics
ST3300007
LW/LC/LCV
Formatted capacity
300.0 Gbytes
Total # of data blocks
585,937,500
(22ECB25Ch)
Cylinders (user accessible) 90,773
Heads (user accessible)
8
Disc rotation ± 5%
10,000 RPM
Operating voltages
+5V
Typical operating
current (amps)
0.68
What you need
• Screwdriver and four 6-32 UNC drive mounting screws
• Forced-air ventilation to provide adequate drive cooling
• An unused drive power connector (not applicable to LC models)
To operate at LVD transfer rates, you may also need an LVD-capable SCSI
host adapter, LVD I/O cable and active negation external terminator.
Multimode interface
This drive can operate in single-ended (SE) or low voltage differential (LVD)
mode. This multimode capability provides backwards compatibility so you
can use it with or without an LVD-capable host adapter. The primary bene-
fits of LVD technology include faster transfer rates, increased allowable
cable lengths, and improved device connectivity.
You can configure the drive to detect between SE and LVD modes automat-
ically or force it to operate in SE mode only. To configure this option, see
Figure 2.
Note. To operate at Ultra2 rates or faster in LVD mode, all devices on the
same bus (cable) must be running in LVD mode. If you add any SE
device to the bus, all devices on that bus operate in SE mode.
Note. Some LVD host adapters provide an LVD connector and an SE con-
nector on the same host adapter to allow you to run SE and LVD
drives concurrently at their maximum capabilities. Check your SCSI
host adapter documentation. See Figure 3.
Caution. Do not mix LVD drives on the same bus with high voltage differ-
ential (HVD) devices—drive damage may occur.
Installation instructions
1. Set the SCSI ID
Determine which SCSI IDs are already being used in the system and then
assign this disc drive a SCSI ID that isn't already being used. Use the J6
connector located on the front of the drive to set the SCSI ID (see Figure 1).
ST3146707
ST373207
LW/LC/LCV
LW/LC/LCV
146.8 Gbytes
73.4 Gbytes
286,749,488
143,374,744
(11177330h)
(88BB998h)
90,773
90,773
4
2
10,000 RPM
10,000 RPM
+12V
+5V
+12V
+5V
1.06
0.78
0.91
0.79
• Most Cheetah
this is the only SCSI drive in your system and there are no other SCSI
devices on the daisychain, you can leave this drive's SCSI ID set to 0 and
proceed to the next step.
• The host system's SCSI controller usually uses SCSI ID 7.
• If you have an LC model drive, the host normally sets the ID over the I/O
interface, so you don't need to worry about this step.
• If you have an LW model drive, some systems provide a cable designed
to connect to the J5 jumper block on the drive to remotely set the ID. You
can connect this cable to J5 and use the host-provided remote switch to
set the SCSI ID. This J5 connector is not present on LC model drives.
Drive
Front
Jumper Plug
(enlarged to
show detail)
SCSI ID = 0
SCSI ID = 1
SCSI ID = 2
SCSI ID = 3
SCSI ID = 4
SCSI ID = 5
SCSI ID = 6
SCSI ID = 7
SCSI ID = 8
SCSI ID = 9
SCSI ID = 10
SCSI ID = 11
SCSI ID = 12
SCSI ID = 13
SCSI ID = 14
SCSI ID = 15
Figure 1.
Setting the SCSI ID (the J5 block is on LW models only)
+12V
2. Configure termination
If you are installing the drive in a system that has other SCSI devices
0.81
installed, terminate only the end devices on the SCSI bus (cable). This drive
does not have internal terminators or any other way of adding internal termi-
nation on the drive. You must provide external termination when termination
is required. This is normally done by adding an inline terminator on the end
of the cable. See Figure 3 for an illustration showing a system configuration
that uses an external terminator.
• Use active (ANSI SCSI-2 Alternative 2) single-ended terminators when
terminating a bus operating in single-ended mode.
• Use SPI-2-compliant active low voltage differential terminators when ter-
minating a SCSI Ultra2 bus operating in LVD mode.
• The host adapter is normally on the end of the bus and internally termi-
nated. You can configure your bus with another device on the end if you
remove termination from the host adapter.
3. Configure terminator power (LW model only)
Terminators have to get power from some source. The default configuration
results in the drive not supplying termination power to the bus. You should
normally leave this drive set at this default unless your host system requires
the drive to supply termination power to the bus. To configure this drive to
supply termination power to the bus, place a jumper on J2 (LW model only)
pins 1 and 2 as shown in Figure 2.
4. Connect the drive activity LED (optional)
Connect the Drive Activity LED cable to J6 pins 11 and 12 (see Figure 2), or
connect a drive ID and Drive Activity LED cable to J5, depending on host
system requirements.
5. Check the other available jumper settings
Select other options on J2 (LW model only) as illustrated in Figure 2. Do not
change these unless instructed to do so by the host system documentation.
®
10K.7 drives are factory set with the SCSI ID set at 0. If
68 Pin
SCSI I/O
+5V
Connector
Pin 1
Pin 1
J6
L
R
Reserved
A
A 2 A 1 A 0
E
E
J1
3
D
S
SCSI ID = 0
(default)
SCSI ID = 1
SCSI ID = 2
SCSI ID = 3
SCSI ID = 4
SCSI ID = 5
SCSI ID = 6
SCSI ID = 7
SCSI ID = 8
SCSI ID = 9
SCSI ID = 10
SCSI ID = 11
SCSI ID = 12
SCSI ID = 13
SCSI ID = 14
SCSI ID = 15
not used
Drive HDA
Rear
J5
J1
Ground
Pin 1
DC Power
4P
3P 2P
1P
(default)
PCBA
A
3 A 2 A 1
A 0

Advertisement

loading

Summary of Contents for Seagate CHEETAH ST3146707LW/LC/LCV

  • Page 1 Cheetah 10K.7 SCSI Installation Guide ST3300007LW/LC/LCV, ST3146707LW/LC/LCV, ST373207LW/LC/LCV Publication Number: 100260917, Rev. A, March 2004 Handling precautions/Electrostatic discharge protection • Disc drives are fragile. Do not drop or jar the drive. Handle the drive only by the edges or frame. •...
  • Page 2 Return Merchandise Authorization (RMA). Before returning the drive, verify that it is defective. Seagate Worldwide customer service centers are the only facilities autho- rized to service Seagate drives. Contact nearest center for return procedures and trade regulations. Shipping the drive Caution.

This manual is also suitable for:

Cheetah st3300007lw/lc/lcvCheetah st373207lw/lc/lcvCheetah 10k.7St3300007lwSt3300007lcSt3300007lcv ... Show all