C1448, C1848, C2148W
Air and Water Cooled User Manual
Product Description & Electrical Requirements
Dimensions
Model
w" x d" x h"
48 x 24 x 29
C1448SA-32
same
C1448SW-32
same
C1448SA-3
same
C1448SW-3
same
C1848SA-32
same
C1848SW-32
same
C1848SA-3
same
C1848SW-3
same
C2148SW-32
same
C2148SW-3
Table notes: Medium cube models have the same
electrical characteristics as Small. Series revision
code omitted.
* Or HACR type circuit breakers.
This manual covers several models. The model
number on the product is located in two places, on
the back dataplate and on the model and serial
number tag, located behind the front panel.
See the illustration for the dataplate and serial tag
locations.
Write the model and serial number of this product
here:
_________________________________________
Electrical
Condenser
208-230/60/1
Air
208-230/60/1
Water
208-230/60/3
Air
208-230/60/3
Water
208-230/60/1
Air
208-230/60/1
Water
208-230/60/3
Air
208-230/60/3
Water
208-230/60/1
Water
208-230/60/3
Water
August 2008
Page 4
Minimum
Suggested
Circuit
Fuse Size
Ampacity
17.7
20
16.0
20
13.6
20
11.9
15
25.5
30
23.8
30
16.5
20
14.8
20
22.2
30
18.0
20
Maximum
Fuse Size*
30
30
30
30
30
30
30
30
30
20