Sato printers operator manual s8408, s8412, s8424 (137 pages)
Summary of Contents for SATO XL4xxe
Page 1
EZ Manual XL4xxe Electric Checks and Adjustments Electric Checks and Adjustment chart Cutter sensor adjustment Ribbon Clutch Adjustment Print Head Balance Adjustment Print Head Position Adjustment home | next Barcode SATO International Pte Ltd...
Page 2
3 Attach positive probe of the Multimeter to the +SIG PIN on the TP Test Module terminal. 4 Turn printer pow er on and rotate the dial to a dial POS on the TP Test Module. Record the values from the Multimeter.
Page 3
Side Hole Sensor Threshold Level Adjustment R Corner Threshold Level Adjustment Jump Hole Sensor Threshold Level Connector PIN No. EZ Manual: XL4xxe Electric Checks and Adjustments Chart 1 < previous | home | next > Barcode SATO International Pte Ltd...
Page 4
If there is difference between the high and low level, adjust VR2 to allow some level difference.) CH2B - CH1A(GND) VR1 and VR9 (Fine adjustment) < previous | home | next Barcode SATO International Pte Ltd >...
Page 5
Middle of level between high and low levels EZ Manual: XL4xxe Electric Checks and Adjustments Chart 3 continued Adjustment to VR CH3B - CH1A(GND) CH4B - CH1A(GND) TP1 - TP4(GND) VR12 < previous | home | next Barcode SATO International Pte Ltd >...
Page 6
EZ Manual: XL4xxe Electric Checks and Adjustments Chart 4 continued Adjustment to VR CH5B - CH1A(GND) TP2 - TP4(GND) VR10 CH6B - CH1A(GND) TP3 - TP4(GND) VR11 < previous | home | next Barcode SATO International Pte Ltd >...
Page 7
Potentiometers are located on FRONT PANEL Adjustment VR Function Print (Print darkness) Cut Position Print Position Display (LCD Darkness) EZ Manual: XL4xxe Electric Checks and Adjustments Chart 5 < previous | home | next > Barcode SATO International Pte Ltd...
Page 8
(–) SG (–) SG (–) SG SW : If you use R-Corner tag, you must be set SW. Other Tags R-Corner Tags EZ Manual: XL4xxe Cutter Sensor Adjustment < previous | home | next > Barcode SATO International Pte Ltd...
Page 9
(+) 7.0 volts : Less than (+) 0.5Volts : More than (+) 6.0Volts to less than (+) 7.0Volts : Less than (+) 0.5Volts EZ Manual: XL4xxe Cutter Sensor Adjustment continued < previous | home | next > Barcode SATO International Pte Ltd...
Page 10
STEPS 1 Switch the printer O FF and disconnect the pow er cable. 2 O pen the top and front access door. Remove the ribbon and label stock if installed.
Page 11
EZ Manual: XL4xxe Ribbon Clutch 500g - 700g 400g - 500g Rewind Unwind Adjustment continued Locking Screw is I nside Adjust Nut Adjust Nut < previous | home | next > Barcode SATO International Pte Ltd...
Page 12
4 If the print is dark at basic frame side, turn the adjust screw to anticlockwise. 5 Finish adjust, then fix the set screw. EZ Manual: XL4xxe Adjust screw Print Balance Adjustment Graduatio n Set Screw < previous | home | next > Barcode SATO International Pte Ltd...
“– ” screw driver. 4 After the adjustment, tighten the set screws and the head mounting screw. Adjust Screw Set Screw EZ Manual: XL4xxe Print Head Position Adjustment < previous | home | next > Barcode SATO International Pte Ltd...