Display Messages - Firex CUCIMAX CBTG180A User Manual

Round pressure bratt pan with mixer touch screen
Table of Contents

Advertisement

02-CBT.A-TOUCH-01-EN
23

DISPLAY MESSAGES

Message
!! BLOCK GAS
DEVICE !!
PRESS
**RESET**
!! GAS SYSTEM
ANOMALY!!
CONTACT TECHNICAL
ASSISTANCE
PROBES ERROR
INTERNAL ERROR
66
Meaning
Safety thermostat has been triggered
The safety thermostat can be disarmed
during transport without any issues.
Insufficient gas pressure.
It is not possible to start cooking.
If a cooking phase has started and
insufficient gas pressure has been
detected on 4 consecutive occasions or
there is a fault on the flame detection
system, the central unit will be interrupted.
Problem with the gas system: gas central
unit fuses, gas solenoid valve, spark plugs
and pilot light plug.
One or more of the appliance's
sensors/probes are faulty (or not
connected). Cooking methods that use
these sensors/probes will be disabled (light
grey) until they are repaired.
Connection error between the relay board
and keypad board
System board error.
DISPLAY MESSAGES
Solution
Reset the thermostat
from the lower panel on
the right hand side, by
pressing firmly on the red
thermostat key.
If the thermostat is
triggered again, contact
the support centre.
Verify that gas is
supplied and that the
pressure is sufficient.
Contact the support
centre.
Press "RESET".
After 3 RESET attempts,
the message below
appears.
Contact technical support.
Contact technical support.
Switch the appliance off,
and switch back on after
two minutes, if the
problem persists, call a
technician

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents