Field Controls EvenAir T32 Installation And User Manual

Thermostat with airflow control

Advertisement

Quick Links

The EvenAir thermostat controls heating, cooling and AIRFLOW to the sleeping and living areas in a
home. The thermostat is installed in the downstairs living area, a wiring hub is installed at the
equipment, one or two wired or wireless temperature sensors are installed in the upstairs sleeping
area and modulating dampers are installed to control the airflow to the living and sleeping areas. The
wiring hub is connected to the thermostat using the existing thermostat wiring. The EvenAir thermostat
can also be used to control humidification and de-humidification, fresh air intake per ASHRAE 62.2,
ERVs or HRVs, whole house fans and economizers.
The EvenAir thermostat monitors the temperature at the sensor and the temperature at the thermostat
every 2 minutes during heating and cooling calls. If the temperatures are different, the EvenAir
thermostat automatically adjusts the modulating dampers 2% to allow additional airflow directed to
the area that needs it for a uniformly comfortable home.
COMPONENTS:
T32 Thermostat
H32 Wiring Hub
AMJ Type Dampers
1 TS51 or 2 TS52 Wired Sensors
READ THESE INSTRUCTIONS CAREFULLY AND COMPLETELY BEFORE PROCEEDING WITH THE INSTALLATION.
This device MUST be installed by a qualified agency in accordance with the manufacturer's installation instructions.The definition of a
qualified agency is: any individual, firm, corporation or company which either in person or through a representative is engaged in, and
is responsible for, the installation and operation of HVAC applicances, who is experienced in such work, familiar with all the precautions
required, and has complied with all the requirements of the authority having jurisdiction.
Installed By:_______________________________________
INSTALLATION AND USER MANUAL
THERMOSTAT WITH AIRFLOW CONTROL
R
F I E L D
C
O
N
T
R
O L
S
Model H32
PN 580011201
Wiring Hub
24VAC, 10VA
Made in USA
MENU
(sold separately)
(sold separately)
(sold separately)
Please retain these instructions after installation.
www.fieldcontrols.com
T32
R
R
Sleeping
Cool
Airflow %
Set To
Schedule
Living
COOL
Day
Living
Tu
SYSTEM
AM
AUTO
MODE
FAN
For Wireless Temperature Sensors
1 or 2 TSER Wireless Sensors
1 ER1 Electronic Receiver Module
Phone: _____________________
R
(sold separately)
(sold separately)
Installation Date: _____________
P/N 780101708 2/18 Rev A

Advertisement

Table of Contents
loading

Summary of Contents for Field Controls EvenAir T32

  • Page 1 INSTALLATION AND USER MANUAL THERMOSTAT WITH AIRFLOW CONTROL F I E L D Model H32 PN 580011201 Wiring Hub 24VAC, 10VA Sleeping Made in USA Cool Airflow % Set To Schedule Living COOL Living SYSTEM AUTO MENU MODE The EvenAir thermostat controls heating, cooling and AIRFLOW to the sleeping and living areas in a home.
  • Page 2: Thermostat Overview

    Thank you for purchasing the EvenAir System from Field Controls. The EvenAir products are compatible with any HVAC system having accessible 24VAC terminals. FEATURES SYSTEM MODES NIGHTTIME OPERATION At night, the EvenAir thermostat uses the temperature sensor in Off, Heat, Cool, Auto. EHeat or emergency heat is available the sleeping area to control heating and cooling calls and when heat pumps are used.
  • Page 3 The EvenAir WiFi thermostat provides remote access to your home’s heating and cooling system EASY UPGRADE TO WIFI and simply plugs into the same subbase and requires no additional wiring. Contact Field Controls technical support for technical information and Field Controls customer support to purchase additional components.
  • Page 4: Thermostat Operation

    HOMEOWNER SECTION THERMOSTAT OPERATION Set Time and Day Set System Mode (Continued) Changing the Setpoint Temperature or RH% Setpoint Touch here to change the time and day of the EHEAT Sleeping week. Emergency Heating Heat Airflow % The UP/DOWN keys are used to change the Sleeping for heat pumps.
  • Page 5: User Options

    HOMEOWNER SECTION THERMOSTAT OPERATION (Continued) Terminating Airflow Override Overriding Automatic Airflow Touch the Airflow % Sleeping To terminate Airflow Sleeping area to override Override, touch the Airflow % Cool Airflow % Cool Set To Set To AUTOMATIC Hold AIRFLOW% area. Living Hold Living...
  • Page 6 HOMEOWNER SECTION USER OPTIONS (Continued) Nighttime Airflow Control On or Off Set the Nighttime Airflow in Heating Set eCool Timer This option is only displayed if a whole house This option is not displayed if Airflow Control This option is not displayed if Airflow Control fan or economizer is installed and controlled has been turned off by the installer using the has been turned off.
  • Page 7: Installer Section

    INSTALLER SECTION This manual is separated into two different sections: one for the Homeowner and one for the System Installer. The Installer section contains setup and installation information of the thermostat with optional user settings available for the homeowner. INSTALLATION Homes with plaster walls with steel lathe may Turn power to the HVAC equipment On.
  • Page 8 INSTALLER SECTION After wiring all components, place the thermostat on WIRING the subbase. Do not install batteries. Turn power to the The T32 thermostat is connected to the wiring hub using the HVAC equipment On and check for startup messages. existing thermostat cable in the home and eliminates having to Set Installer Options and then test the installation using install any new wires within the living area of the home when...
  • Page 9: Installer Options

    INSTALLER SECTION INSTALLER OPTIONS These set up features should only be accessed by a qualified installer during initial EvenAir thermostat installation set up. The homeowner would not normally access these product set up features. Option Description Display Range Default As Installed Equipment Type GE or HP Heat Pump Type...
  • Page 10: Minimum Run Time

    INSTALLER SECTION ACCESSING INSTALLER OPTIONS 03 Outdoor Balance Point 08 Gas Heating Minimum Off Time Factory Default: 0 Minutes. Range: 0 to 9 Minutes (Only displayed if Heat Pump and Dual To access the Installer Options, TOUCH Fuel selected.) Use the UP/DOWN HOLD the hidden Enter key for 7 seconds until Option...
  • Page 11: Economizer Control

    INSTALLER SECTION 21 Minutes of Fresh Air per Hour For Whole House Fan or Economizer wiring 14 Vacant Cooling Setpoint information, see the H32 Wiring Hub Factory Default: 80F. Range: 74F to 95F (Only displayed if Fresh Air Control is ON) Installer Manual.
  • Page 12: Humidifier Control

    INSTALLER SECTION 34 Economizer/Whole House 42 De-Humidication Control 53 Maximum Airflow in Heating to Fan Control by Timer the Sleeping Area Factory Default: OFF. Range: On or Off. (Only displayed if Whole House Fan or Select if de-humification is used during cooling Factory Default: 150%.
  • Page 13: Install Batteries

    INSTALLER SECTION No Power 58 Home Number for Install batteries only after If the the LCD is blank there is no power from the Wireless Sensors s u c c e s s f u l l y t e s t i n g t h e wiring hub.
  • Page 14: Maintenance And Troubleshooting

    MAINTENANCE AND TROUBLESHOOTING THERMOSTAT OPERATION SENSOR INSTALLATION Problem - nC is displayed on thermostat. Problem - nS message on thermostat. nC is displayed on the thermostat when the thermostat loses For wired sensors, check that the sensor is wired correctly. communication with the wiring hub.
  • Page 15 SPARE PARTS AND ACCESSORY LIST Field Controls Model Description Part Number Number 580011106 Programmable, communicating thermostat w/ airflow control, for all equipment. 580011107 T32WF Programmable, communicating thermostat w/ airflow control for all equipment. WiFi enabled. Wiring Hub for gas/electric, conventional or dual fuel heat pump equipment with 3 Heat/2 Cool 580011201 Wired temperature sensor for the sleep area.
  • Page 16: Warranty

    This manual may be downloaded and printed from the Field Controls website (www.fieldcontrols.com) WARRANTY For warranty information about this or any Field Controls product, visit: www.fieldcontrols.com Field Controls Technical Support 1.800.742.8368 fieldtec@fieldcontrols.com Field Controls Customer Service 1.252.522.3031 sales@fieldcontrols.com 9154 Stellar Ct Phone: 252.522.3031...

This manual is also suitable for:

Evenair t32wf

Table of Contents