Field Controls EvenAir T21WF Installation And User Manual

Thermostat with airflow control

Advertisement

Quick Links

Wi
The EvenAir WiFi thermostat controls heating, cooling and AIRFLOW to the sleeping and living
areas in a home and provides remote access to your HVAC system using a smart phone, tablet or
PC. The thermostat is installed in the downstairs living area, a temperature sensor is installed in the
upstairs bedroom area and two modulating dampers are installed to control the airflow to the
living and sleeping area.
The EvenAir thermostat monitors the temperature at the sensor and the temperature at the
thermostat every 2 minutes during heating and cooling calls. If the temperatures are different, the
EvenAir thermostat automatically adjusts the modulating dampers 2% so that more airflow is
directed to the space that needs it for a uniformly comfortable home.
COMPONENTS:
EvenAir T21WF Thermostat
EvenAir TS51 or TS52 Wired Temperature Sensor(s) (sold separately)
EvenAir AMT Type Motorized Damper, With Terminals (sold separately)
READ THESE INSTRUCTIONS CAREFULLY AND COMPLETELY BEFORE PROCEEDING WITH THE INSTALLATION.
This device MUST be installed by a qualified agency in accordance with the manufacturer's installation instructions.The definition of
a qualified agency is: any individual, firm, corporation or company which either in person or through a representative is engaged in,
and is responsible for, the installation and operation of HVAC applicances, who is experienced in such work, familiar with all the
precautions required, and has complied with all the requirements of the authority having jurisdiction.
Installed By:_______________________________________
INSTALLATION AND USER MANUAL
THERMOSTAT WITH AIRFLOW CONTROL
Sleeping
Airflow %
WiFi
Living
Day
Tu
AM
MENU
MODE
Fi
Please retain these instructions after installation.
www.fieldcontrols.com
T21WF
R
R
Cool
Set To
Schedule
COOL
Living
SYSTEM
AUTO
FAN
F I
E L
D
C
Phone: _____________________
R
O
N
T
R
O L
S
Installation Date: _____________
P/N 780101703 3/18 Rev A

Advertisement

Table of Contents
loading

Summary of Contents for Field Controls EvenAir T21WF

  • Page 1 EvenAir thermostat automatically adjusts the modulating dampers 2% so that more airflow is directed to the space that needs it for a uniformly comfortable home. COMPONENTS: EvenAir T21WF Thermostat EvenAir TS51 or TS52 Wired Temperature Sensor(s) (sold separately) EvenAir AMT Type Motorized Damper, With Terminals (sold separately) READ THESE INSTRUCTIONS CAREFULLY AND COMPLETELY BEFORE PROCEEDING WITH THE INSTALLATION.
  • Page 2: Thermostat Overview

    Thank you for purchasing the EvenAir System from Field Controls. The EvenAir products are compatible with any HVAC system having accessible 24VAC terminals. FEATURES AIRFLOW LIMITS SYSTEM MODES Off, Heat, Cool, Auto Maximum airflow limits can be set for heating and cooling modes during installation.
  • Page 3 HOMEOWNER SECTION HOMEOWNER This manual is separated into two different sections: one for the Homeowner and one for the System Installer. The Homeowner section contains information on features and operation of the thermostat along with optional user settings available to the homeowner. THERMOSTAT OPERATION AND USER SETTINGS Features User Options...
  • Page 4: Thermostat Operation

    HOMEOWNER SECTION THERMOSTAT OPERATION Set Time and Day Set Fan Mode Temperature Override Touch here to change the time and day of the Touch the key to change the FAN MODES - To override the setpoint temperature: AUTO or ON. week.
  • Page 5: User Options

    HOMEOWNER SECTION USER OPTIONS Automatic Airflow Control On or Off Factory Set Schedule Nighttime Airflow Control (cont.) The thermostat comes pre-set with the This option is only displayed if User Airflow Default start time for Nighttime Airflow is following energy-saving schedule for Control has been turned On by the installer in 10:00pm but can be changed using User the Installer Options.
  • Page 6 HOMEOWNER SECTION USER OPTIONS (continued) Start Linking WiFi Thermostat Clean the Touch Screen INSTALL / REPLACE AA BATTERIES This option disables the touch screen for 30 This option starts the linking of the EvenAir Two AA batteries power seconds to enable the user to clean the touch thermostat to the home’s WiFi network.
  • Page 7: Installer Section

    INSTALLER SECTION This manual is separated into two different sections: one for the Homeowner and one for the System Installer. The Installer section contains setup and installation information of the thermostat with optional user settings available to the homeowner. INSTALLATION CAUTIONS ATTENTION INSTALLER Before installing the EvenAir comfort system, turn off...
  • Page 8 INSTALLER SECTION INSTALL DAMPERS WIRING Install a damper with an AMT actuator in the duct supplying air Warning! to the sleeping area and wire the terminals to the Turn the power to the HVAC equipment off before wiring. corresponding terminals on the T21. Install a second damper with an AMT actuator in the duct supplying air to the living area Gas/Electric, 2H/1C and wire it to the T21.
  • Page 9: Temperature Sensor Wiring

    INSTALLER SECTION TEMPERATURE SENSOR WIRING WIRING DIAGRAM Warning! Sleeping Area Turn the power to the HVAC equipment off before wiring. Damper Use 2-conductor, 18 or 20 gage, thermostat cable to wire from the T21WF Thermostat to the temperature sensor in the sleeping area.
  • Page 10: Installer Options

    INSTALLER SECTION INSTALLER OPTIONS These set up features should only be accessed by a qualified installer during initial EvenAir thermostat installation set up. The homeowner would not normally access these product set up features. Record Installed Selection if Changed Option Description Display Range...
  • Page 11: Minimum Run Time

    INSTALLER SECTION ACCESSING INSTALLER OPTIONS 03 Setting the Compressor Stages 08 Minimum Run Time Factory Default: 2 Min. Range: 0 to 9 Min. Factory Default: 1 . Range: 0 or 1 To access the Installer Options, TOUCH Use the UP/DOWN This option is used to set the number of HOLD the hidden Enter key for 7 seconds until...
  • Page 12 INSTALLER SECTION 13 Calibrate Living Area Temperature Sensor 18 Enable USER Airflow Control 23 Maximum Airflow in Cooling to the Living Area Factory Default: None. Factory Default: Off. Range: On or Off. Factory Default: 140%. Range: 100% to 160%. Range - +/-5 Homeowners with an unusual work schedule, Use the UP/DOWN...
  • Page 13 INSTALLER SECTION 03-04 Testing Heating Airflow Limits 05-06 Testing Cooling Airflow Limits ACCESSING THE TEST MENU This test is used to determine the maximum This test is used to determine the maximum The Test Menu is used to test the Indoor Fan allowable airflow to the sleeping area and the allowable airflow to the Sleeping and Living Operation, Allowable Heating Airflow Limits and...
  • Page 14: Install Batteries

    INSTALLER SECTION Error Messages: Install batteries only after successfully testing the installation using the Installer Test Menu. Blank LCD INSTALL BATTERIES When the equipment is The batteries power the clock powered up, a blank LCD when 24VAC power is lost. Slide indicates that there is no power the battery cover downward and to the thermostat.
  • Page 15: Maintenance And Troubleshooting

    Turn off the Nighttime Airflow Control option using the what the homeowner feels is the correct temperature using User Options. Installer option 13 for the living area and option 14 for the sleeping area. SPARE PARTS AND ACCESSORY LIST Field Controls Model Description Part Number Number 580011101...
  • Page 16 This manual may be downloaded and printed from the Field Controls website (www.fieldcontrols.com) WARRANTY For warranty information about this or any Field Controls product, visit: www.fieldcontrols.com Field Controls Technical Support 1.800.742.8368 fieldtec@fieldcontrols.com Field Controls Customer Service 1.252.522.3031 sales@fieldcontrols.com 9154 Stellar Ct Phone: 252.522.3031...

This manual is also suitable for:

Evenair t21

Table of Contents