GE TMO2D User Manual

GE TMO2D User Manual

Panametrics display and control module

Advertisement

GE
Measurement & Control Solutions
Gas & Moisture
TMO2D Digital Display
User's Manual

Advertisement

Table of Contents
loading

Summary of Contents for GE TMO2D

  • Page 1 Measurement & Control Solutions Gas & Moisture TMO2D Digital Display User’s Manual...
  • Page 2 BERG ENGINEERING & SALES CO., INC. • • 3893 Industrial A venue Rolling Meadows, IL 60008 phone: (847) 577-3980 •fax: (847) 577-0474 Your Complete Source for NDT Testing Equipment Since 1969! • www.bergeng.com info@bergeng.com...
  • Page 3 Measurement & Control Solutions TMO2D Digital Display User’s Manual 910-084 Rev. D August 2011...
  • Page 5 Make sure that operators and maintenance personnel have all safety equipment applicable to the auxiliary equipment. Examples include safety glasses, protective headgear, safety shoes, etc. Unauthorized Operation Make sure that unauthorized personnel cannot gain access to the operation of the equipment. TMO2D Digital Display User’s Manual...
  • Page 6 Environmental Compliance Waste Electrical and Electronic Equipment (WEEE) Directive GE Measurement & Control Solutions is an active participant in Europe’s Waste Electrical and Electronic Equipment (WEEE) take-back initiative, directive 2002/96/EC. The equipment that you bought has required the extraction and use of natural resources for its production. It may contain hazardous substances that could impact health and the environment.
  • Page 7: Table Of Contents

    2.4 Wiring Other Components to the TMO2D Display........
  • Page 8 6.4 Ordering Information ................. .63 Appendix A. Outline and Installation Drawings Appendix B. Menu Maps TMO2D Digital Display User’s Manual...
  • Page 9: Chapter 1. Features And Capabilities

    Chapter 1. Features and Capabilities Chapter 1. Features and Capabilities 1.1 Overview This chapter presents the features and capabilities of the TMO2D Digital Display. It also includes a brief list of GE transmitters that can be used with the TMO2D Digital Display. 1.2 Introduction The TMO2D Digital Display offers a number of important features: •...
  • Page 10 Chapter 1. Features and Capabilities TMO2D Digital Display User’s Manual...
  • Page 11: Chapter 2. Installation

    TMO2-TC and XMTC. 2.3.1 TMO2 Transmitter This section describes how to interconnect the TMO2 and TMO2D. The TMO2 can be wired for internal or external compensation. Each type of compensation requires a different cable. Before you make any connections, make sure you have the appropriate cable.
  • Page 12 2.3.1b Wiring: Use the following steps to interconnect the TMO2 to the TMO2D. 1. Route the cable into the TMO2 transmitter through one of the 3/4" conduit holes on the side of the transmitter. WARNING! Be sure to plug the unused conduit/cable entry hole on the transmitter, in order to meet specifications and to maintain the appropriate weatherproof or explosion-proof rating.
  • Page 13 4. Tighten the side screws, and carefully plug TB1 back onto the TMO2 PCB. 5. Connect the other end of the cable in a similar manner to the TMO2D. Refer to Figure 11 on page 17 for TB1 location.
  • Page 14 Note: If you make the modifications as discussed here, your unit will comply with the EMC Directive 2004/108/EC. Note: For CE compliance, the I/O cables must be shielded. The shields are to be grounded within the TMO2D to the closest location.Shielded cable is not required when installations include metal conduit.
  • Page 15: Xmo2 Transmitter

    2.3.2 XMO2 Transmitter Wiring the XMO2 oxygen transmitter to the TMO2D display requires use of the X4(*) cable, which can support distances up to 450 ft (130 m). For longer distances, each cable can be supplied as 18-AWG that can be located up to 1,050 ft.
  • Page 16 6. Tighten the side screws, and carefully plug terminal block TB1/TB2 back onto the XMO2 PCB. 7. Connect the other end of the cable in a similar manner to the TMO2D. Refer to Figure 11 on page 17 for the TB1 location.
  • Page 17 Note: If you make the modifications as discussed here, your unit will comply with the EMC Directive 2004/108/EC. Note: For CE compliance, the I/O cables must be shielded. The shields are to be grounded within the TMO2D to the closest location. Shielded cable is not required when installations include metal conduit.
  • Page 18: Tmo2-Tc Transmitter

    2.3.3 TMO2-TC Transmitter Connecting the TMO2-TC thermal conductivity transmitter to the TMO2D requires use of the X3(*) or Y3(*) cables. The X3(*) cable can be used for distances up to 450 ft (130 m). For longer distances, each cable can be supplied as 18-AWG that can be located up to 1,050 ft (320 m).
  • Page 19 2.3.3a Wiring: (cont.) 4. Tighten the side screws, and carefully plug TB1 onto the PCB. 5. Connect the other end of the cable in a similar manner to the TMO2D. Refer to Figure 11 on page 17 for TB1 location.
  • Page 20: Xmtc Transmitter

    2.3.4 XMTC Transmitter Connecting the XMTC thermal conductivity transmitter to the TMO2D requires use of the X4(*) or Y4(*) cables. The X4(*) cable can be used for distances up to 450 ft (130 m). For longer distances, each cable can be supplied as 18-AWG that can be located up to 1,050 ft (320 m).
  • Page 21 4. Tighten the side screws, and carefully plug TB1 back onto the XMTC PCB. 5. Connect the other end of the cable to the TMO2D. Refer to Figure 11 on page 17 for TB1 location. +24 VDC Line (red) 1 –24 VDC Return (blk) 2...
  • Page 22 Note: If you make the modifications as discussed here, your unit will comply with the EMC Directive 2004/108/EC. Note: For CE compliance, the I/O cables must be shielded. The shields are to be grounded within the TMO2D to the closest location. Shielded cable is not required when installations include metal conduit.
  • Page 23: Rs-232C Serial Port

    RS-232C protocol. Connect the RS-232C from the computer or terminal to the rear of the TMO2D using a 25-pin connector. (See Figure 10 below for the RS-232 wiring pin connections, and Chapter 3 for the corresponding key chart.)
  • Page 24 Chapter 2. Installation TMO2D Digital Display User’s Manual...
  • Page 25 Chapter 2. Installation TMO2D Digital Display User’s Manual...
  • Page 26 Chapter 2. Installation TMO2D Digital Display User’s Manual...
  • Page 27: Chapter 3. Operation

    To power up the benchtop TMO2D, press the red power key to the right of the display. Other TMO2D models have no power switch, and begin operating when the external power to which they have been connected has been turned on.
  • Page 28: The Keypad

    Figure 12: The TMO2D Display 3.4 RS-232C Serial Port The TMO2D contains a bidirectional, industry-standard RS-232C serial port which can be connected to a terminal or computer that supports the RS-232C protocol (see The Outputs Menu on page 30.) All keypad and most display operations can be performed remotely through this serial port.
  • Page 29: Chapter 4. Basic Programming

    This user program has six main menus. Use the front panel keypad and display to check or change the settings for current operating parameters. The TMO2D stores data in memory and will retain it for several years if the main power is lost.
  • Page 30: Key Functions

    The [] key enables you to scroll forward through the menu options; it is equivalent to pressing the [NO] key in the Menu Mode. 4.3 Programming the TMO2D Using the Display This section briefly explains display and menu navigation, and then takes you step-by-step through the programming procedure.
  • Page 31: Menu Navigation

    These submenus allow you to alter operating parameters. Once entered, these values remain in the display memory until you change them. (Appendix B offers a flow diagram of the Setup Menu in Figure 26 on page 79.) TMO2D Digital Display User’s Manual...
  • Page 32: Set Time

    Note: A period (.) must be used to separate the numbers. Enter Date (MM.DD.YY): Press [YES] to confirm the entry, and [YES] again to exit. [2.24.02] SETUP MENU Press [NO] to proceed to the next submenu. Set Date? TMO2D Digital Display User’s Manual...
  • Page 33: Set Gas/Units/Scaling

    If you have selected one of the five preprogrammed gases, the program returns to the Set Gas/Units/Scaling? submenu. However, if you have selected OTHER, the TMO2D asks for a gas label. A specific label can contain up to 8 characters.
  • Page 34: Set Backlight

    INCR or DECR selections, and continue pressing [YES] until you have adjusted the contrast to your conditions. Then select DONE and press [YES] to exit. SETUP MENU Press [NO] to proceed to the next submenu. Set Contrast? TMO2D Digital Display User’s Manual...
  • Page 35: Set Display

    4.4.6 Set Display? Although this feature is not commonly used, the TMO2D, when used with the TMO2, can display compensation values for pressure or the percentage of background gas. For the analyzer to display these values, the TMO2 must include external compensation.
  • Page 36 TMO2D will immediately change to the new baud rate. Display and keyboard operation will not be correct until the baud rate of the terminal is changed to match the new baud rate set in the TMO2D. SET COMMUNICATIONS Press [YES] to set the update rate.
  • Page 37: Set Error Handling

    The Set Error Handling? submenu enables the TMO2D to handle inputs it receives that are outside its measurement range. Based on directions it receives, the TMO2D can show the errors on the display and force an output high or low.
  • Page 38: The Outputs Menu

    The TMO2D provides a choice of one isolated 0/4-20 mA output, or two isolated 0/4-20 mA outputs. You can set both options for a 0 to 20-mA or a 4-20 mA response, and scale the output anywhere within the range of the transmitter.
  • Page 39: The Relays Menu

    4.6 The Relays Menu The third main menu is the Relays Menu. The TMO2D includes two or four single-pole double throw (SPDT) relays for use in activating alarm devices or driving automatic calibration solenoid valves. The display addresses the relays as A, B, C or D.
  • Page 40: Autocalibration Type

    Relay type: [ALARM] autocalibration selection. 4.6.1 Autocalibration Type If you select Autocalibration, the TMO2D asks for the Auto-Calibration option: Use the [NO] or arrow keys to select the autocalibration type, and press [YES] to Auto-Cal Relay Type: [PROC/CAL] zero/span confirm the selection.
  • Page 41 Press [NO] to proceed to the cal error action entry. Set System Fault Action? The calibration error could occur if the TMO2D performs an autocal on a transmitter and the amount of drift exceeds a programmed limit. You can set the limits in Change AutoCal Limits? on page 59.
  • Page 42: The Tests Menu

    Chapter 4. Basic Programming 4.6.2 Alarm Type (cont.) Users can configure the TMO2D alarms for either normal or failsafe mode. For normal alarm configuration, the alarm contact remains de-energized until an alarm condition occurs. For failsafe mode, the alarm contact remains energized until an alarm condition occurs, when it becomes de-energized.
  • Page 43: Dvm Test

    Press any key to return to the DVM submenu. X.XX mA 4.7.1a Done? Select DVM Input: Press [NO] to scroll to “Done?” and press [YES] to exit the DVM test. Done? TESTS Press [NO] to proceed to the Output submenu. DVM Test? TMO2D Digital Display User’s Manual...
  • Page 44: Output Test

    Use the [NO] or arrow keys to select A, and press [YES] to confirm the selection. [A] B done Note: If you select a calibration relay to test, the TMO2D displays the following warning: Use the [NO] or arrow keys to choose to continue (or not) with the test, and press Warning! Cal-Relay, Test? [NO] [YES] to confirm the selection.
  • Page 45: The Calibration Menu

    Select Response? • Select Compensation? • Gas Calibration? • Pressure Calibration? • Auto Cal Parameters? (Refer to Figure 28 on page 81 and Figure 29 on page 82 for a flow diagram of the Calibration Menu.) TMO2D Digital Display User’s Manual...
  • Page 46: Select Response

    Use the [NO] or arrow keys to select the type of compensation desired. Then press Select Compensation: [NONE] pres bkgd [YES] to confirm the selection. CALIBRATION MENU Press [NO] to proceed to the “Gas Calibration?” submenu and enter data. Select Compensation? TMO2D Digital Display User’s Manual...
  • Page 47: Gas Calibration

    Press [YES] twice to confirm each entry. The menu will then display the “Working . . .” message before returning to the Gas Calibration? submenu. CALIBRATION MENU Press [NO] to proceed to Pressure Calibration. Gas Calibration? TMO2D Digital Display User’s Manual...
  • Page 48 4.8.3c Background Compensation: Background gas compensation in the TMO2D is typically used with a TMO2 oxygen transmitter to correct the readings for changes in background gas concentrations. If you have selected background compensation (BKGD), you must enter background grid data.
  • Page 49: Pressure Calibration

    4.8.4 Pressure Calibration? The Pressure Calibration? submenu enables users to directly calibrate the pressure transducer. While this menu option is always displayed, it should only be programmed and used when the TMO2D is used with a TMO2 calibrated for atmospheric pressure compensation.
  • Page 50: Auto Cal Parameters

    At the specified time interval, the TMO2D activates a solenoid valve on a sampling system using one of the relays provided. This procedure isolates the transmitter from the process stream and connects the transmitter to one of the calibration gases.
  • Page 51 Auto verification is similar to automatic calibration. The solenoids are still tripped to allow the calibration gases to flow to the transmitter. However, if the calculated drift is less than a preprogrammed amount, the TMO2D will not store the new drift data into memory. If the drift is beyond the verification limit and no cal error occurs, then the TMO2D applies new calibration data and sets a new calibration flag.
  • Page 52 Note: The number of days entered at this prompt can be no higher than the number of days entered at the “Days” prompt above. AUTO CALIBRATION MENU Press [NO] to proceed to the “Set AutoCal Mode?” option. Set Time Interval? TMO2D Digital Display User’s Manual...
  • Page 53 For example, to set the zero gas in a 2-gas cal mode for 0.00% oxygen for an equilibration time of 3 minutes: AUTO CALIBRATION MENU Scroll through the submenu, and press [YES] to enter the Set Zero Gas option. Set Zero Gas? TMO2D Digital Display User’s Manual...
  • Page 54 Press [NO] to proceed to the Set Settling Time option. Set Span Gas? Note: In the 1-gas cal mode, entering offset gas data is similar to entering the zero or span gas data described above. TMO2D Digital Display User’s Manual...
  • Page 55 In the Set Settling Time option, you can enter (in minutes and seconds) the settling time, the amount of time the process gas should remain on before the TMO2D resumes taking measurements and reactivates the recorder output. (During an autocal, the recorder output from the TMO2D has been locked to the last value it had sent directly before the autocal began.) AUTO CALIBRATION MENU Scroll through the submenu, and press [YES] to enter the Set Settling Time option.
  • Page 56 Press [NO] to proceed to the next item. Set Output Response? AUTOCAL ERROR EFFECTS Press [YES] to exit the Error Effects submenu. Done? AUTO CALIBRATION MENU Press [NO] to proceed to the Perform Auto Cal? option. Set Error Handling? TMO2D Digital Display User’s Manual...
  • Page 57 At the end of the Auto Cal procedure, the Process/Cal relay will reset to the Process position and the settling time will count down to zero. The display will then read AutoCal in Progress and the TMO2D will return to the start of the Perform Auto Cal? option.
  • Page 58 After counting down the settling time, the display returns to the start of the “Perform AUTO CALIBRATION MENU Perform AutoCal? Auto Cal?” option. Press [NO] to proceed to the “Reset Drift?” option. TMO2D Digital Display User’s Manual...
  • Page 59 Then press [NO] to exit the Auto Cal Parameters submenu. Auto Cal Parameters? 4.8.5j Done? CALIBRATION MENU Press [YES] to exit the Calibration Menu and return to the Main Menu. Done? MAIN MENU Press [NO] to proceed to the System Log menu. Calibration? TMO2D Digital Display User’s Manual...
  • Page 60: The System Log Menu

    Note: Testing the fault alarm does not appear in the System Log. The TMO2D stores only the 25 most recent events in its memory. When additional events occur, the TMO2D discards the oldest event from the log to make room for the new event. Refer to Figure 29 on page 82, for a flow diagram of the System Log menu.
  • Page 61: Viewing The System Log

    4.9.1 Viewing the System Log The System Log may be viewed on the TMO2D display, or transmitted to a computer, printer or other data acquisition system using the RS232 serial port. To view the System Log on the TMO2D display, scroll through the Main Menu...
  • Page 62: Print System Log

    To print the System Log or transmit it over the RS232 serial port: SYSTEM LOG MENU Press [YES] and the TMO2D transmits the entire log using the RS232 serial port. Print System Log? A System Log printout appears similar to the example shown in Figure 15 below.
  • Page 63: Chapter 5. Advanced Programming

    5.1 Introduction In addition to its basic program, the TMO2D analyzer contains a factory setup program that enables the user to perform more advanced operations on the parameters that have been first installed at the factory. This program has eight main menus.
  • Page 64: Set Significant Digits

    Note: This option applies only if you select display in ppm ranges. If the TMO2D is set up for the 10 ppm range, it defaults to 2-digit resolution. However, you can change the significant digits in this menu.
  • Page 65: Select Tracking

    Chapter 5. Advanced Programming 5.5 Select Tracking? If you use a background gas, the Select Tracking? option enables the TMO2D to use the last data point as the starting point for the calculation. FACTORY SETUP MENU Press [YES] to select tracking.
  • Page 66: Labcal Outputs

    Use the [NO] or arrow keys to scroll to another output to repeat the calibration done procedure. Press [YES] to confirm the entry. If you have completed calibration, scroll to “Done” and press [YES]. FACTORY SETUP MENU Press [NO] to proceed to the Manual Offset? option. LabCal Outputs? TMO2D Digital Display User’s Manual...
  • Page 67: Manual Offset

    5.10Change AutoCal Limits? The Change AutoCal Limits? option enables you to adjust the error handling limits for auto calibration. (To program basic auto cal parameters, refer to Auto Cal Parameters on page 42.) The TMO2D has default values for error handling: •...
  • Page 68 Edit Tot Drift Limit prompt.) Press [YES] to exit the Factory Setup Menu and resume taking measurements. FACTORY SETUP MENU Resume? (Pressing [NO] returns the menu to the Set Significant Digits? prompt.) TMO2D Digital Display User’s Manual...
  • Page 69: Chapter 6. Specifications

    Power: 100/115/230/240 VAC ±10%, 50/60 Hz, 35 watts max., provides 24 VDC, 1.2 A max. to transmitter Fuses: • 110/120 VAC: 0.5 A, Slo-Blo • 220/240 VAC: 0.25 A, Slo-Blo. Temperature: • Operating: 0 to +50°C (+32 to +122°F) • Storage: -20 to +70°C (-4 to +158°F) TMO2D Digital Display User’s Manual...
  • Page 70: Physical

    Weatherproof, fiberglass: NEMA 4X, IP65 • Weatherproof, stainless steel: NEMA 4X • Explosion-proof: Consult factory. European Compliance: This unit complies with EMC Directive 2004/108/EC and 2006/95/EC Low Voltage Directive. (Installation Category II, Pollution Degree 2) TMO2D Digital Display User’s Manual...
  • Page 71: Ordering Information

    4. Dual alarm relays and autocal**, hermetically-sealed for Class I, Div. 2 F-Analyzer 1. For use with oxygen analyzer 2. For use with gas analyzer *Approved for Division 2 with Division 2 alarms **Dual automatic calibration relays (autocal) TMO2D Digital Display User’s Manual...
  • Page 72 Chapter 6. Specifications TMO2D Digital Display User’s Manual...
  • Page 73: Appendix A. Outline And Installation Drawings

    Figure 22: Oxygen Display PC Board Assembly • Figure 23: Oxygen Display PC Board Schematic, sht 1 • Figure 24: Oxygen Display PC Board Schematic, sht 2 • Figure 25: Oxygen Display PC Board Schematic, sht 3 • TMO2D Digital Display User’s Manual...
  • Page 74 Appendix A. Outline and Installation Drawings TMO2D Digital Display User’s Manual...
  • Page 75 Appendix A. Outline and Installation Drawings 19.00 (483) 9.00 (229) 0.25 (6.4) 2.25 5.25 (57) (133) Notes: 1. Dimensions are in inches (millimeters). 2. All dimensions are reference. 3. Depth = 9.85 (250) TMO2D Digital Display User’s Manual...
  • Page 76 Appendix A. Outline and Installation Drawings 9.00 (229) 9.85 (250) Power 5.25 (133) TMO2D – • Panametrics Display and Control Module 2.27 (58) Notes: 1. Dimensions are in inches (millimeters). 2. All dimensions are reference. TMO2D Digital Display User’s Manual...
  • Page 77 5.22 (79) (107) (133) TMO2D – • Panametrics Display and Control Module 1.03 (26) 0.50 (13) 0.50 9.19 (233) 0.50 (13) (13) 8.00 (203) 0.265 (6.7) Dia (4 places) Note: Dimensions are in inches (millimeters). TMO2D Digital Display User’s Manual...
  • Page 78 3.40 2.250 (107.2) (86) (57.2) 5.22 (133) 1.48 0.25 .410 (10.4) (38) ref. 0.91 0.375 (9.5) .125 (3.2) R (23) 0.43 (11) 4 places typ. both ends 8.75 (222) Note: Dimensions are in inches (millimeters). TMO2D Digital Display User’s Manual...
  • Page 79 9.38 (238) Ref. Ref. 4 places 0.75 11.43 (273) (290) Ref. 4.35 (110) 1.50 1.50 0.88 (22) Dia. thru (38) (38) 2 places Note: Dimensions are in inches (millimeters). 8.72 (116) 2.00 (51) NOT TO SCALE TMO2D Digital Display User’s Manual...
  • Page 80 8.93 (227) 6.00 (152) Ref. 4.00 (102) 10.75 11.37 (273) (289) Ref. TMO2D Panametrics Display and Control Module Note: Dimensions are in inches (millimeters). 0.88 (22) Dia. thru 1.50 1.50 2 places (38) (38) 2.00 (51) TMO2D Digital Display User’s Manual...
  • Page 81 Appendix A. Outline and Installation Drawings TMO2D Digital Display User’s Manual...
  • Page 82 Appendix A. Outline and Installation Drawings TMO2D Digital Display User’s Manual...
  • Page 83 Appendix A. Outline and Installation Drawings TMO2D Digital Display User’s Manual...
  • Page 84 Appendix A. Outline and Installation Drawings TMO2D Digital Display User’s Manual...
  • Page 85: Appendix B. Menu Maps

    Figure 26: Main Menu: Setup and Outputs • Figure 27: Main Menu: Relays and Tests • Figure 28: Main Menu: Calibration Menu • Figure 29: Main Menu: Calibration (AutoCal Param.), System Log & Resume • Figure 30: Factory Setup Menu • TMO2D Digital Display User’s Manual...
  • Page 86 Appendix B. Menu Maps TMO2D Digital Display User’s Manual...
  • Page 87 Force High? Force Low? OTHER Gas Label Set Update Rate? Output A Value Output B Value Set Backlight? Set Data Interval Done? [XXX] Remain ON Min [X] Set Time Stamp? Print Time Done? Stamp? Done? TMO2D Digital Display User’s Manual...
  • Page 88 Done Done? Set System Fault Action? Turn Relay X: Done Trip on System Faults Note: After entering numeric values, press the [YES] key twice, once to enter and once Done? to confirm the new value. TMO2D Digital Display User’s Manual...
  • Page 89 X Curves X.XX %O2, X.X mmHg X Points Enter Point? Repeat for X.XX %O2, Curve #1 X Points O2 mA [X.XX] X.XX %O2, Curve #1 X.XX %O2, Bkgd mA [X.XX] X.X mmHg O2 mA [X.XX] TMO2D Digital Display User’s Manual...
  • Page 90 Drift Values . . . No Effect Force High Force Low (Or "No Points 1 Gas 2 Gas in Curve") Force to Value Hold Last Value Cal Type Output A [X.XX] Offset Span Done? Output B [X.XX] Done? TMO2D Digital Display User’s Manual...
  • Page 91 Cal? Window 4 mA output [XX.XX] [X.XX] Drift mA [X.XX] Note: After entering numeric values, press [YES] Verification twice, once to enter and once to confirm the new value. Limit? Drift mA [X.XX] Done? TMO2D Digital Display User’s Manual...
  • Page 92 Appendix B. Menu Maps TMO2D Digital Display User’s Manual...
  • Page 93 ........3 Wiring TMO2D Digital Display User’s Manual...
  • Page 94 ....22 Programming the TMO2D ..... . 82 System Log Menu Map TMO2D Digital Display User’s Manual...
  • Page 95 ....28 Update Rate in Setup Menu ....21 User Program, Entering Data TMO2D Digital Display User’s Manual...
  • Page 96 Index TMO2D Digital Display User’s Manual...
  • Page 97 AUTHORIZATION NUMBER (RAN), and shipping instructions for the return of the instrument to a service center will be provided. 2. If GE Sensing instructs you to send your instrument to a service center, it must be shipped prepaid to the authorized repair station indicated in the shipping instructions.
  • Page 98 Warranty TMO2D Digital Display User’s Manual...
  • Page 99 1100 Technology Park Drive Billerica, MA 01821 declare under our sole responsibility that the TMO2D Display and Control Module to which this declaration relates, is in conformity with the following standards: • EN 61326-1: 2006, Class A, Table 2, Industrial Locations •...
  • Page 102 Customer Support Centers U.S.A. The Boston Center 1100 Technology Park Drive Billerica, MA 01821 U.S.A. Tel: 800 833 9438 (toll-free) 978 437 1000 E-mail: sensing@ge.com Ireland Sensing House Shannon Free Zone East Shannon, County Clare Ireland Tel: +353 61 61470291 E-mail: gesensingsnnservices@ge.com An ISO 9001-2008 Certified Company www.ge-mcs.com/en/about-us/quality.html...

Table of Contents