Functions
system will operate with the settings valid before the initialization at the
next system start.
While the initialization is executed, the output data status may become un-
defined temporarily.
Procedure
1.
+ switch power ON
After the start-up screen, the digital display shows "Init".
The memory is initialized and the system is set to RUN mode

4.3.1.2 Save

There are different methods to save setting changes permanently so that after a system re-
start the new settings are applied:
In the control panel of the sensor head: Access the option to be changed via the func-
tion menu and confirm the change with
With the MI input: Input the MI signal for 480ms to save the current settings (see page
26).
NOTE
It is not possible to save the state of the timing input (TM). The timing input
will be OFF right after the system is switched ON or when you select a dif-
ferent memory.
When you change settings with a serial command, a dedicated console
(sold separately), or the setting and monitoring software HL-G1SMI, you
need to save the changes and restart the system, or the system will operate
with the old settings valid before the change at the next system start.

4.3.2 Function Menu in Setting Mode

Access the functions by pressing the [ENTER] key on the control panel (see page 43) for 2
seconds. The currently selected function or setting is shown in the digital display.