1 Indication to the manual

This operating manual gives basic instructions which
are to be observed during installation, operation and
maintenance of the pump. It is therefore imperative
that this manual be read by the responsible personnel
and operator prior to assembly and commissioning. It
is always to be kept available at the installation site.
1.1
Identification of safety instructions in the
operating manual
Safety instructions given in this manual non-
compliance with which would affect safety are identi-
fied by the following symbol
Safety sign according with ISO 3864 - B.3.1
or where electrical safety is involved, with:
Safety sign according with ISO 3864 - B.3.6
Where non-compliance with the safety instructions
may cause a risk to the machine and it's function the
word
ATTENTION
is inserted.

2 Description of the Product

2.1
General description of the pump
Pumps of this type are one-stage rotary pumps where
the impellers are fixed on the driving shaft extension.
The pump shaft and motor shaft are interconnected
by means of a shaft clamp. Pump and motor form a
compact and space-saving unit.
The have a cantilever construction and operated with
half speed.
Vertically mounted pumps are equipped with a mount-
ing flange. The pump end immerses into the tank and
the motor extends vertically above the tank.
BAS6554
Brinkmann Vortex Pumps of the Series SFT1554-C
8 Servicing and Maintenance ............................... 6
9 Troubleshooting Guide ...................................... 7
10 Spare Parts ..................................................... 8-9
11 Repair ................................................................ 9
12 Disposal ............................................................. 9
13 WARRANTY .................................................... 10
2.2
Intended use
The immersion pumps of the series SFT are suitable
for handling contaminated coolants within the limiting
application in accordance with table 1.
Limit of Application (Table 1)
Type
Mediums
Chip material
Chip geometry
Particle-size in
the medium
Kinetic viscosity
of the medium
Temperature of
medium
min. delivery
volume
Dry running
Motor cycle
time per hour
Ambient
temperature
Set-up altitude
The pumps are to be operated within their design
limits. Applications outside of these limits are not
approved. The manufacturer is not responsible for any
damages resulting from use of the pumps in such
applications.
05/2017
Edition
SFT
Coolant, cooling- and cutting-oils
Aluminium, steel, coloured steels
max. chip to coolant ratio by weight:
1.5%
Flow chips up until 3.15 inch (80
mm) long
The max. ball diameter is
1.77 Inches (45 mm)
1.57 Inches (40 mm)
2
...66 SSU (...12 mm
/s)
30 ... 140 °F (0 ... 60 °C)
1.5% of Q max.
Dry running causes increased wear
and should be avoided.
During the test of the direction of
rotation (< 30 s) permissible.
The pump SFT should be operated
in continual operation mode, not
pulsed mode.
104 °F (40 °C)
3280 ft (1000 m)
ATTENTION
Page 2 of 10