PERFORMANCE

Design life
10,000 hour continious operation at 10 l/minute at 20 _C
7,000 hour continious operation at 10 l/minute at 45 _C
or:
100,000 cycles operation (ON = 5 s/OFF = 5 s) at 10 l/minute
at 45 _C.
After life test accuracy must be within ±5% of measured
value at first stage.