3-8. Wiring Instructions for Inter-unit Connections

(1) Insert the inter-unit wiring (according to local codes)
into the through-the-wall PVC pipe. Run the wiring
toward the indoor side allowing approx. 10 inch to
extend from the wall face. (Fig. 19)
(2) Route the inter-unit wiring from the back of the
indoor unit and pull it toward the front for connection.
(Fig. 20a, 20b)
(3) Connect the inter-unit wiring to the corresponding
terminals on the terminal plate (Fig. 20a, 20b) while
referring to the wiring diagram.
(4) Be sure to secure the wiring with the provided
clamp.
How to remove the cover plate
To access the terminal plate inside the indoor unit, follow
these steps.
(1) Using a Phillips screwdriver, take out the screw on
the cover plate. (Fig. 20a, 20b)
(2) Remove the cover plate.
Rear
panel
Wiring
Cover plate
Earth
plate
9
Plastic
cover
10 in.
Fig. 19
Terminal
plate
Fig. 20a
Inter-unit
control line
wiring
Lock nut
Top of conduit
connector
Fig. 20b
Wall