PROGRAMMING MODE -
Diagnostic tests:
This program has been added for testing the washer and detecting errors.
Entering the test mode
Data Name
1. Entering programming mode
Entering
2. MEDICAL 90
the test mode
3. START
1 1
According to pressing START button, test move to the next step.
Number of times the
START button is pressed
None
1time
Turns on all lamps and locks the door
2 times
Tumble Clockwise.
3 times
Low Speed Spin
4 times
High Speed Spin
5 times
Inlet valve for main water turns on.
6 times
Inlet valve for hot wash turns on.
7 times
Inlet valve for softener turns on.
8 times
Inlet valve for bleach turns on.
9 times
Tumble counter clockwise.
10 times
Turn on the heater
11 times
Drain Pump turns on
12 times
Turn on Circulation Pump
13 times
Turns on all lamps.
14 times
Button Checks.
15 times
High Speed Spin
16 times
17 times
Note
• Make sure the drum is empty when a diagnostic test is performed. Do not use
(display)
Button
Display
Check Point
PDA Signal Check
Test Mode
Description
Push and hold the MEDICAL 90 and NORMAL 60 at the same time.
After that push NORMAL 75 button for 3 times. Push START button.
Press the MEDICAL 90 button. Then
display.
Enter the diagnostic test mode.
Displayed EU XX and LE XX alternately
(Version)
rpm (40~50)
rpm (600)
rpm (1000)
Water level frequency (261~)
Water level frequency (261~)
Water level frequency (261~)
Water level frequency (261~)
rpm (40~50)
Displayed 0XX
Water level frequency (261~)
Displayed 0XX
Displayed EU XX and LE XX alternately
Displayed EU XX and LE XX alternately
rpm(1000)
this function is not applied in this machine
appears in the
Display
.
1 9

Advertisement