American Standard Green Tea 3571 Installation And Operation Manual

American Standard Green Tea 3571 Installation And Operation Manual

Bath waste and overflow with toe tapper drain plug & deck mount bath filler
Hide thumbs Also See for Green Tea 3571:

Advertisement

INSTALLATION AND
OPERATION MANUAL
Green Tea
®
Models 3571, 3573
THANK YOU...
for selecting an American Standard bath. Your new bath is shipped to you after careful inspection. All you need
to finish the installation are your selected fittings.
To ensure maximum performance and pleasure from this product, please follow the instructions and cautions.
WARNING: Risk of hyperthermia and possible drowning. People using medications and/or having adverse medical
!
history should consult a physician before using this product.
!
WARNING: Risk of personal injury. Do not overfill bathtub before entering. Entering tub when filled more than 2/3 can
cause overflow and slippery conditions. Exercise caution when entering and exiting.
!
WARNING: No Food or Alcoholic Beverages. Use of your bathtub immediately after meals is not recommended.
Avoid alcohol consumption before or during bathing. Alcoholic beverages can cause drowsiness or hyperthermia
resulting in loss of consciousness or even drowning.
Use this unit only for its intended use as described in this manual.
Do not use any attachments not recommended by American Standard.
INSTALLATION AND FRAMING INSTRUCTIONS
Each bath arrives ready for installation however, a drain/overflow kit is required for each bath and it is not included.
The variety of installations for this bath may require framing procedures other than those shown. Locate studs as required.
Ensure roughing-in dimensions are proper, plumb, and square.
Remove the bath from the carton. Retain the shipping carton until satisfactory inspection of the product has been
!
made. Do not lift the bath by the plumbing at any time; handle by the shell only.
All bath units are factory tested for proper operation and watertight connections prior to shipping. Prior to
!
installation, the bath must be filled with water and operated to check for leaks that may have resulted
from shipping damage or mishandling.
The sumps of these baths are supported by feet and no additional sump support is required. Once the
!
bath is in place, the feet should be shimmed and secured accordingly so that the rim of the bath
contacts the stringer or pier but supports no weight.
It is strongly recommended that an additional opening be provided for access to drain components.
!
Each bath has a nominal length (L), width (W), and Height (H) along with a rim height. Unless otherwise noted
!
in the following rough-in references, assume that the nominal tolerances are as much as +/-1/4 inch (6mm).
Therefore, it is strongly recommended that the installer build the surrounding structure after receiving the actual
bath. Structural measurements should be verified against the actual bath received to ensure proper fit.
For questions or service issues, please call Technical Support 1-(800)-442-1902.
Please do not contact or return product to the store.
All product names listed herein are trademarks of AS America, Inc. unless otherwise noted.
Bathtubs
1
755741-100 EN

Advertisement

Table of Contents
loading

Summary of Contents for American Standard Green Tea 3571

  • Page 1 Models 3571, 3573 THANK YOU... for selecting an American Standard bath. Your new bath is shipped to you after careful inspection. All you need to finish the installation are your selected fittings. To ensure maximum performance and pleasure from this product, please follow the instructions and cautions.
  • Page 2 MOUNTING ROUGH-IN REFERENCES FOR ROUGH-IN REFERENCES FOR SURFACE PIER TYPE INSTALLATIONS RECESS TYPE INSTALLATIONS WATERPROOF SEALANT AS DESIRED BATH CUTOUT CUTOUT DESIRED LEVELING STRINGERS TYPICAL TILE BEAD INSTALLATION TILE WALLBOARD SEALANT NOTE: FRONT EDGE OF BATH MUST BE SUPPORTED BY STUD WALL. TILE BATH BEAD...
  • Page 3: Specifications

    SPECIFICATIONS: SIDE VIEW END VIEW DRAIN / OVERFLOW GENERAL SPECIFICATIONS FOR GREEN TEA BATH TUBS Description Dimensions Drain / Height to Cut Out Rough-In Tub Edge to Weight with Product Gallon to L-W-H Overflow Underside Pier Recess Centerline Water / Floor Weight Overflow of Deck...
  • Page 4 AS America, Inc. Limited Lifetime Warranty for Tubs and Shower Bases AS America, Inc. (”American Standard”) warrants to the original consumer purchaser that it will, at its option, repair or replace this tub/shower base – are found by American Standard, in its sole judgment, to be defective under normal residential use and maintenance so long as it is owned by the original consumer purchaser.
  • Page 5 Installation Instructions DEEP SOAK™ BATH DRAIN 1640.305.XXX BATH WASTE AND OVERFLOW WITH TOE TAPPER DRAIN PLUG Note: THIS DRAIN IS INTENDED FOR USE WITH BATH DRAINS ONLY! Thank you for selecting American-Standard...the benchmark of fine quality for over 100 years. To ensure that your installation proceeds smoothly--please read these instructions carefully before you begin.
  • Page 6 INSTALL DRAIN PLUG AND ELL (STANDARD AND OVER-THE-RIM DRAINS) Apply putty to underside of DRAIN PLUG (1) and drop into drain outlet. PUTTY Slip RUBBER WASHER (2) on from below and thread DRAIN PLUG (1) into DRAIN ELL ASSEMBLY (3). BATH DRAIN OUTLET NOTE: TUB IS SHOWN CUT AWAY FOR CLARITY OF INSTALLATION.
  • Page 7 ABOVE FLOOR OUTLET INSTALLATION (STANDARD DRAIN) Note: Waste outlet can be installed either above the floor or below floor. Fig.1. For above floor drain outlet, Rotate DRAIN TEE ASSEMBLY (1) 90 degrees so TAILPIECE (2) faces out the back from tub as shown. ROUGH FLOOR ABOVE FLOOR ROUGH BELOW FLOOR ROUGH...
  • Page 8: Product Number

    DEEP SOAK™ BATH DRAIN BATH WASTE AND OVERFLOW WITH TOE TAPPER DRAIN PLUG PRODUCT NUMBER 1640.305.XXX 754129-0070A OVERFLOW HOLD RING REPAIR KIT 754053-YYY0A OVERFLOW CAP REPAIR KIT 754068-0070A OVERFLOW FITTING 753980-YYY0A TOE TAPPER DRAIN 753983-YYY0A DRAIN PLUG 751977-0070A DRAIN PLUG WASHER Replace the "YYY"...
  • Page 9: Recommended Tools

    FLUENT ® 7186.910 DECK MOUNT BATH FILLER Thank you for selecting American Standard... the benchmark of fine quality for over 100 years. To ensure that your installation proceeds smoothly-please read these instructions carefully before you begin. Certified to comply with ANSI A112.18.1M...
  • Page 10: Valve Assembly

    VALVE ASSEMBLY • Install LOCKNUTS (1) and RUBBER WASHERS (2) onto valve shanks. • Slide HOSE CONNECTOR (10) onto VALVE BODY (4). Slide HOSE CONNECTOR G1/2 (11) onto TEE (5) Slide HOSE (3) MOUNTING assembly into opening of both VALVE BODIES (4) and TEE (5). SURFACE Tighten HOSE CONNECTOR (10) and (11) firmly.
  • Page 11: Install Handles

    INSTALL HANDLES • Turn hot and cold VALVE STEMS (1) to the off position. • Push ADAPTER (2) onto VALVE STEM (1), so the recess in ADAPTER (2) is facing toward the back wall. VIEW “A”. Install and tighten STEM SCREW (3) to secure ADAPTER (2).
  • Page 12: Care Instructions

    HAND SHOWER INSTALLATION • Install RUBBER RING (2) on SPRAY ESCUTCHEON (1) and install SPRAY ESCUTCHEON (1) through fifth hole on tub ledge (12" max from Spout) making sure the SPRAY ESCUTCHEON (1) opening is directed toward tub center. Install RUBBER WASHER (3) and LOCKNUT (4) on to SPRAY ESCUTCHEON (1) from underside of ledge.
  • Page 13 FLUENT ® DECK MOUNT BATH FILLER MODEL NUMBER 7186.910 M964926-YYY0A LEVER HANDLE (LEFT) M964927-YYY0A LEVER HANDLE (RIGHT) 918319-0070A M970261-0070A A922388-YYY0A SCREW SET SCREW KIT STREAM STRAIGHTENER M918464-0070A 911903-0070A SPINDLE RUBBER RING 918555-0070A 030274-0070A SCREW 954559-0070A SHANK M918026-0070A DIVERTER MOUNTING KIT HANDLE ADAPTER 1660207-XXX HAND SHOWER...