P2E3Ds3 Ds3 Pdh Module; Uds-114 P2E3Ds3 Ds3 Pdh Module - Alcatel-Lucent 9500 MPR Product Information

Hide thumbs Also See for 9500 MPR:
Table of Contents

Advertisement

3EM23952AA
Issue 01, September 2009
UDS-114

P2E3DS3 DS3 PDH Module

FEATURES AND APPLICATION NOTES
DESCRIPTION
INDICATORS, CONNECTORS, AND CONTROL
P2E3DS3 DS3 PDH Module
Terminates up to two DS3 signals.
Framed DS3 Bi-Directional alarm management
Bi-Directional performance monitoring on framed DS3 signals
Encapsulation of DS3 data flows into standard Ethernet packets Inter
Working Function (IWF)
Extraction of DS3 data flows from standard Ethernet packets IWF
Supports both unprotected and 1+1 EPS protected configurations
The P2E3DS3 module provides 2 DS3 interfaces. The MSS-8 shelf supports up
to six P2E3DS3 modules or 12 unprotected DS3 interfaces or 6 protected DS3
interfaces.
The P2E3DS3 are supported in MSS-8 slots 3 through 8 for unprotected radio
configurations. In protected radio configurations, a pair of P2E3DS3s are
required. The main P2E3DS3s are equipped in slots 3, 5, or 7 and the protect
(spare) P2E3DS3s are equipped in the slots directly across from the main (slots
4, 6, or 8). The protect (spare) P2E3DS3 module protects the radio if the main
P3E3DS3 fails.
The P2E3DS3 DS3 PDH module has the following indicator and connectors.
See figure
114-1
for P2E3DS3 DS3 PDH module front panel indicator and
connectors.
UDS-114