Clean and Replace Heater / Air Conditioner Filter

Clean Circulating Air Filter

--- every 500 hours

Replace Circulating Air Filter

--- After cleaning 6 times or so
f
NOTE: The recommended maintenanse hour is a reference
value. Shorten the maintenance interval when the machine is
operated in dusty areas.
Removing Recirculating Air Filter
1. Open left-side panel (1) located under the seat.
2. Grasp and pull tab (3) of circulation filter (2) to remove
filter (2). Filter (2) can be folded at the middle part. Pull
the filter while folding it. Take care so that it does not
interfere with pedals.