Omega BB702 User Manual

Omega BB702 User Manual

Blackbody calibrator

Advertisement

TM
User's Gui d e
Shop online at
omega.com
e-mail: info@omega.com
For latest product manuals:
www.omegamanual.info
BB702
Blackbody Calibrator

Advertisement

Table of Contents
loading

Summary of Contents for Omega BB702

  • Page 1 User’s Gui d e Shop online at omega.com e-mail: info@omega.com For latest product manuals: www.omegamanual.info BB702 Blackbody Calibrator...
  • Page 2 Fax: (203) 359-7700 e-mail: info@omega.com For Other Locations Visit omega.com/worldwide The information contained in this document is believed to be correct, but OMEGA accepts no liability for any errors it contains, and reserves the right to alter specifications without notice.
  • Page 3: Table Of Contents

    5.3 Fuse Replacement ..............5-1 Section 6 Reference Probe ................. 6-1 Section 7 Specifications ................7-1 Section 8 Troubleshooting Guide ............8-1 Section 9 Glossary of Terms Used in This Manual ......9-1 Section 10 The OMEGA Family of Blackbody Calibrators ....10-1...
  • Page 4 Back Panel ..................3-2 Menu Hierarchy Showing Factory Default Settings ....3-4 Programming Procedure ............3-4 Heat Up / Cool Down Cycle Time Table ........ 3-5 Connecting the BB702 to a Computer’s Serial Port ....4-1 Internal Reference Probe Connections ........6-1...
  • Page 5: Section 1 - Introduction

    BB702 Introduction Section 1 - Introduction Your BB700 Series Blackbody Calibration Source has been designed for ease of use and reliability whenever you have the need to test or calibrate non-contact infrared temperature instruments. It is important that you read this manual completely and follow all safety precautions before operating this instrument.
  • Page 6: General Desrciption

    Figure 1. IEC symbols General Description The Model BB702 is a portable, rugged, bench-top, blackbody calibration source with a built-in precision PID digital controller. The calibrator is used to test and calibrate infrared pyrometers. The 2.5 inch Diameter target plate has an emissivity of 0.95 and can be set to any temperature between ambient +11 to...
  • Page 7: Section 2 - Installation

    5 to 45°C (41 to 113°F). Ambient Temperature The target plate of the BB702 can achieve any temperature within the specified tem- perature range when being operated in ambient temperature up to 32.2°C (90°F). When operating the unit at higher ambient temperatures, the user must not exceed the “Maximum Allowable Target Plate Temperature”...
  • Page 8: Power Connection

    Power Connection Standard (115 VAC~, 50/60 Hz models) The BB702 comes with a standard North American 3-prong AC power cord. Do not use any other power cord other than the one provided. This cord provides the proper grounding and has been safety tested by the proper safety agencies.
  • Page 9: Section 3 - Operation

    IR detector of the pyrometer. CAUTION: The BB702’s target plate can be set to very high temperatures. Exercise extreme caution when operating the unit. Keep hands and fingers away from the target plate area. Keep flammable products such as paper, plastics and clothing far from the BB702.
  • Page 10: Back Panel Connections

    BB702 Operation NOTE: P.I.D. Control: Proportional, integral, derivative control ( P.I.D.) is a temperature control algorithm used in high-end temperature controllers. The controller causes the process to attain the desired temperature by turning the process on or off. The process may be a heater or refrigerator. As the process temperature approaches the setpoint temperature the hot or cold process will be pulsed to reduce the corrective measures and minimize overshooting.
  • Page 11: Changing The Temperature Setpoint

    BB-702. A detailed description of this port is described in Section 4. Changing the Temperature Setpoint The layout of the front panel is shown in Figure 3. The BB702 incorporates a PID digital setpoint controller. The upper display indicates the blackbody target plate temperature known as (PV) Process Variable, while the lower display indicates the programmed setpoint known as (SV) Setpoint Variable.
  • Page 12: Menu Hierarchy Showing Factory Default Settings

    BB702 Operation Menu 00 Menu 01 Menu 02 Menu 03 Menu 04 Menu 05 Ac.Cd = 02 Ac.Cd = 03 Ac.Cd = 04 Ac.Cd = 05 Key Lock SETPOINT Ac.Cd Gn.o1 ALr1 id.no SnSr Gr.o2 ALr2 BAUd 12.o.7 Sn.00 rAtE Cy.t1...
  • Page 13: Heat-Up/Cool-Down Cycle Times

    If an overheat condition occurs, let the unit cool off for one hour (leave the unit on), then press the reset button, firmly. If the reset switch keeps resetting, call OMEGA’s Customer Service Department. 3-5...
  • Page 14: Connecting The Bb702 To A Computer's Serial Port

    The RS232 port is optically isolated to eliminate ground loop problems. Below is a pinout diagram for the serial port of the BB702 as well as the pinout for a 9-pin PC serial port. Use a straight DB9 (female) to DB9 (male) connector cable to connect your computer to the BB702.
  • Page 15 BB702 Communications Parameter List (only relevant parameters shown): PAR#: Parameter: Range/Units: Process Temp. Input determined Setpoint Input determined Baud Selection bAUd Baud Selections: Code: Baud: Parity: Data Bits: Stop Bits: 3.o.7 6.o.7 12.o.7 1200 2 (factory default settings) 24.o.7 1200 3.n.8...
  • Page 16: Maintenance

    For continued protection against the risk of fire replace with only the same size, type and rating fuse indicated here and on the rear panel of your unit. For model: BB702 use 1 ea. 250 VAC~, T1A (Time-Lag, 1 Amp) UL./CSA APPROVED (0.25"...
  • Page 17: Section 6 - Reference Probe

    BB702 Reference Probe Section 6 - Reference Probe An electrically isolated 100Ω Class A RTD probe has been embedded into the target plate heater assembly to be used as a reference. This feature is commonly used in conjunction with a precision thermometer, ohmmeter or temperature recording device.
  • Page 18: Specifications

    BB702 Specifications Section 7 - Specifications Target Plate Temperature Range: Amb. + 11 to 215°C (Amb. + 20 to 420°F) Accuracy: ±0.5°C, ±0.25% rdg (±0.9°F, ±0.25% rdg) Stability: ±0.1°C (±0.2 °F ) Ambient Environmental Conditions Temperature: 5 to 45 °C (41 to 113°F)
  • Page 19: Troubleshooting Guide

    BB702 Troubleshooting Guide Section 8 - Troubleshooting Guide Problem Solution 1. Unit will not turn on. a. Check Power Cord connections. b. Check rear panel fuse(s). c. Unit requires service, contact our customer service department. 2. Unit turns on but the target a.
  • Page 20: Glossary Of Terms Used In This Manual

    BB702 Glossary of Terms Used in This Manual Section 9 - Glossary of Terms Used in This Manual Blackbody A theoretical object that radiates the maximum amount of energy at a given temperature, and absorbs all the energy incident upon it.
  • Page 21: The Omega Family Of Blackbody Calibrators

    The OMEGA Family of Blackbody Calibrators The OMEGA Family of Blackbody Calibrators Listed below is a selection guide of OMEGA’s current line of blackbody calibration sources in addition to the one you have selected. This family of rugged, portable and...
  • Page 22 NOTES: 10-2...
  • Page 23 Department will issue an Authorized Return (AR) number immediately upon phone or written request. Upon examination by OMEGA, if the unit is found to be defective, it will be repaired or replaced at no charge. OMEGA’s WARRANTY does not apply to defects resulting from any action of the purchaser, including but not limited to mishandling, improper interfacing, operation outside of design limits, improper repair, or unauthorized modification.
  • Page 24 Where Do I Find Everything I Need for Process Measurement and Control? OMEGA…Of Course! Shop online at omega.com TEMPERATURE M U Thermocouple, RTD & Thermistor Probes, Connectors, Panels & Assemblies M U Wire: Thermocouple, RTD & Thermistor M U Calibrators & Ice Point References M U Recorders, Controllers &...