WATER OUTLET AND WATER SEAL

The condensate water outlet is located in the
center of the merchandiser. The outlet has an
external water seal installed from the factory.
This water seal drains into the condensate
evaporation pan located beneath the merchan-
diser. Remote models have a fan to circulate
air around the base to keep condensation from
forming.
NOTE: All lower base panels must be in place
when the refrigerator is operating. If not,
airflow from the condenser (self-contained)
will be directed over the evaporation pan and
defrost water in the pan may overflow.
Refrigeration lines are under pressure.
Refrigerant must be recovered before
attempting any connection or repair.
P/N 0515957_M
/ r
EfrIgEratIon
U.S. & Canada 1-800-922-1919 • Mexico 01 800-890-2900 • www.hussmann.com
When brazing pipes, be sure to use the
insulation blanket shipped with the
merchandiser to prevent damage to the
metal merchandiser bottom.
Product will be degraded and may spoil if
allowed to sit in a non-refrigerated area.