HP StorageWorks XP10000 User Manual page 74

Business copy xp
Hide thumbs Also See for StorageWorks XP10000:
Table of Contents

Advertisement

Table 25
BC error codes (continued)
Error
Description
Code
0801
The BC feature could not be used.
080B
The request could not be accepted.
0810
The specified command cannot be accepted in this
status. (The command was rejected.)
0811
The specified command is treated as an NOP.
0812
The new pair could not be created because a path
group is set.
0813
The Pairsplit command was issued to a pair in the
PSUS status.
0814
The Paircreate command was issued to the pair in
the PAIR status.
0817
A Reserve volume cannot be set because a path
group is set.
0818
The Pairresync or Pairsplit-E command cannot be
issued because a path group is set.
081F
Command Reject. P-VOL is used from HOST or by
CA.
0830
A pair cannot be created because the track format
is different.
0831
A pair cannot be created because a number of
slots is different.
0834
The emulation type of the specified P-VOL is not
supported by BC.
0835
The emulation type of the specified S-VOL is not
supported by BC.
0836
The pair cannot be created.
0840
Logical contradiction.
0841
Logical contradiction.
0842
Logical contradiction.
0848
Logical contradiction.
0849
Logical contradiction.
084A
Logical contradiction.
084B
Logical contradiction.
74
Business Copy XP (BC) for the XP10000/XP12000
Corrective Action
Ensure that the disk array has the correct
microcode level for BC, the disk array has BC
installed and enabled, and the Command View XP
management station or XP Remote Web Console
has BC installed and enabled.
Retry about one minute later.
Check the pair status, and ensure that the pair
status is correct for the command.
The specified command is treated as an NOP.
(NOP means the command can end without errors,
but executes nothing.)
Disconnect from host, or cancel Continuous Access
XP path.
On the Continuous Access XP main screen, confirm
the specified S-VOL is simplex, specify the
Pair by Force
option, and retry the operation.
The Pairsplit command cannot be issued because
the pair is already in PSUS status.
The Paircreate command cannot be issued because
the pair is already in PAIR status.
Disconnect volume to be reserved from host, or
delete Continuous Access XP path.
Unmount the S-VOL (offline from the host), or delete
Continuous Access XP path.
Disconnect from host, or cancel Continuous Access
XP path.
Ensure that the emulation type of the P-VOL and
S-VOL is the same.
Ensure that the capacity of the P-VOL and S-VOL is
the same.
Ensure that BC supports the emulation type of the
P-VOL.
Ensure that BC supports the emulation type of the
S-VOL.
The emulation type of the P-VOL and S-VOL is not
the same.
Call HP technical support for assistance.
Call HP technical support for assistance.
Call HP technical support for assistance.
Call HP technical support for assistance.
Call HP technical support for assistance.
Call HP technical support for assistance.
Call HP technical support for assistance.
Delete

Advertisement

Table of Contents
loading

This manual is also suitable for:

Storageworks xp12000

Table of Contents