Controls And Adjustments - Hussmann SMG8B Installation & Operation Manual

Medium temperature self contained
Table of Contents

Advertisement

P/N 3018126_E
Refrigeration Controls
Product
Model
Application
SMG
Medium Temp.
(Dairy, Deli,
Produce)
SSG
Medium Temp.
(Dairy, Deli)
1. The Dixell XR75 Controller controls
refrigeration temperature. This is factory
installed in the control panel. Measure
discharge air temperatures at the center of the
honeycomb.
For low temperature models, defrosts are
time initiated and temperature terminated.
The defrost setting is factory set as shown. To
ensure a thorough defrost, the defrost must
be terminated by the temperature termination
setting — not by time. For medium
temperature models, defrost is time initiated
and temperature terminated.
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A.

CONTROLS and ADJUSTMENTS

Discharge Air
Discharge Air
Temperature
Temperature
Cut In
24° F
25° F
21° F
26° F
Defrost
Discharge Air
Frequency
Temperature
Cut Out
(per day)
1
19° F
1
17° F
START UP
Follow the Dixell XR75 start up procedures as
detailed on Page 3-1 of this manual.
Each self contained merchandiser has its own
evaporator coil and a pre-set thermostatic
expansion valve (TEV). The TEV has been
factory set at design conditions to provide the
recommended performance.
Defrost Controls
Failsafe
Type of
Time
Defrost
(Minutes)
90
Off Time
90
Off Time
SMG8B & SSG8B
3-7

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ssg8b

Table of Contents