Induction Cooktop (CTI) Series Induction Cooktop (CTI) Series Troubleshooting Guide DIAGNOSTICS MODE To enter Diagnostics Mode, the unit must be in Lock CLEAR Mode (see Section 3, Electronic Control, page 3-6, for a description of how to put the unit into Lock Mode). Press and hold the universal OFF key for 5 seconds, the controls will enter Diagnostics Mode 1.
Page 3
Induction Cooktop (CTI) Series Induction Cooktop (CTI) Series Troubleshooting Guide CONTROL TEMPERATURE TEST (Third Test) 1. To enter Control Temperature Test, press the “+” key of the 3000W inductor controls. The 3000W bar graph will show 4 LEDs. 2. The 3-digit display illuminates Ambient Control Temperature in °F. Press the “-”...
Page 4
Induction Cooktop (CTI) Series Induction Cooktop (CTI) Series Troubleshooting Guide SOFTWARE VERSION (Seventh Test) 1. To enter Software Version, press the “+” key of the 3000W element controls. The 3000W bar graph will show 15 LEDs. 2. The Timer display will illuminate the software version (scrolling if necessary). 3.
Page 5
Induction Cooktop (CTI) Series Induction Cooktop (CTI) Series Troubleshooting Guide Error Mode Error codes are organized in a priority-based scheme which allows for different behavior based on the priority of the error. There are three priority levels, defined as follows: Priority 1: Priority 1 errors are considered safety related or of such catastrophic scope that the control is considered inoperable.
Page 6
Induction Cooktop (CTI) Series Induction Cooktop (CTI) Series Troubleshooting Guide ERROR DISPLAYED ERROR POSSIBLE SOURCE(S) OF NOTES PRIORITY ERROR # CONDITION FAILURE / ACTION REQUIRED No Indicator Power loss The control panel will turn off display and shut off all burners.
Page 7
Induction Cooktop (CTI) Series Induction Cooktop (CTI) Series Troubleshooting Guide ERROR DISPLAYED ERROR POSSIBLE SOURCE(S) OF NOTES PRIORITY ERROR # CONDITION FAILURE / ACTION REQUIRED Generator 1: Burners associated with 1. Faulty cable connection Comm. Error generator 1 disabled, if Action: Check (J1, J2, or J3) connections.
Page 8
Induction Cooktop (CTI) Series Induction Cooktop (CTI) Series Troubleshooting Guide ERROR DISPLAYED ERROR POSSIBLE SOURCE(S) OF NOTES PRIORITY ERROR # CONDITION FAILURE / ACTION REQUIRED Generator 1: Effected burner is not LED board failure. Burner (F,FR,FC) available. Action: Perform LED test #1 and if all ‘ON LED’...
Page 9
Induction Cooktop (CTI) Series Induction Cooktop (CTI) Series Troubleshooting Guide ERROR DISPLAYED ERROR POSSIBLE SOURCE(S) OF NOTES PRIORITY ERROR # CONDITION FAILURE / ACTION REQUIRED Generator 1: The effected burner will 1. Induction generator failure. Shorted heat sink shutdown. Action: Perform Heatsink test #4 and if thermistor.