Graco GT 750 Instructions Manual page 10

Grease pump
Table of Contents

Advertisement

Service
Reassembly
1. Apply a thin layer of grease to o-ring (17*) and
throat seal (19*)and install parts in pump base (21)
(F
. 9).
IG
2. Apply a thin layer of grease to o-ring (29*) and
install o-ring to packing gland (2). Tighten down
packing gland (2) to pump base (F
NOTE: Throat seal (19*) should be installed with the
lips pointed down towards the bottom of the pump.
2
29
19*
21
17 *
F
. 9
IG
3. Reattach pump base (21) to air motor (1) using 3
mounting bolts (23). Torque mounting bolts to 60
ft-lb (81.35 N•m) (F
IG
21
23
F
. 10
IG
10
. 9).
IG
. 10).
4. Replace piston seal (22*) on valve housing piston
(7) (F
. 11).
IG
5. Screw the connecting rod (4) into the valve housing
(6) and adjust the ball travel as instructed in Check
Valve Adjustment on page 12 Tighten nut (5) to 60
ft-lb (81.35 N•m) (F
IG
5
4
22*
7
F
. 11
IG
6. Apply a thin layer of grease to piston seal (22*).
Reinstall down tube (20) into pump base (21).
Torque to 100 to 150 ft-lb (135.6 to 203.4 N•m) (F
12).
21
20
F
. 12
IG
. 11).
6
3A5363B
.
IG

Hide quick links: