High pressure air-assisted, 4000 psi (28 mpa, 280 bar) maximum working fluid pressure, 100 psi (0.7 mpa, 7 bar) maximum working air pressure (28 pages)
Series a pressure roller 3600 psi (24.8 mpa, 248 bar) maximum fluid inlet pressure (4 pages)
Summary of Contents for Graco 309489
Page 1
President Air Motor ....306982 GRACO INC. P.O. BOX 1441 MINNEAPOLIS, MN 55440-1441 Copyright 2003, Graco Inc. is registered to I.S. EN ISO 9001...
D This equipment is for professional use only. D Read all instruction manuals, tags, and labels before operating the equipment. D Use the equipment only for its intended purpose. If you are not sure, call your Graco distributor. D Do not alter or modify this equipment.
Page 3
Moving parts can pinch or amputate your fingers. D Keep clear of all moving parts when starting or operating the pump. D Before checking or servicing the equipment, follow the Pressure Relief Procedure on page 8 to prevent the equipment from starting unexpectedly. 309489...
Page 4
D Know the specific hazards of the fluid you are using. D Store hazardous fluid in an approved container. Dispose of hazardous fluid according to all local, state and national guidelines. D Always wear protective eyewear, gloves, clothing and respirator as recommended by the fluid and solvent manufacturer. 309489...
NOTE: Reference numbers and letters in parentheses refer to callouts in the Figs. and parts drawing. 5. Fluid supply container: follow your local code. NOTE: Always use Genuine Graco Parts and Acces- 6. Object being sprayed: follow your local code. sories, available from your Graco distributor.
Page 6
For assistance in designing a system to time the gun trigger is released. When used with a suit your needs, contact your Graco representative. Relax-A-Valve set in the automatic position, fluid Mount the pump to suit the type of installation planned.
Page 7
Air Line Filter Air Line Lubricator Pump Air Regulator Drain Valve (part of 38, Evenflor Valve) Pump Ground Wire Grounded Fluid Hose Grounded Air Hose Evenflor Control Knob (rear of valve) Evenflor Valve By–pass Tube Evenflo Air Regulator 1/2” Minimum ti3003a7 309489...
Now clear 6. Gradually adjust the pump and applicator air the tip or hose. pressure as needed during normal operation. 309489...
Page 9
Refer to the Technical Data on page 16 up, flush the system with a compatible solvent as often for the maximum air and fluid working pressure of as necessary to prevent a build up of dried fluid in the this pump. pump or hoses. 309489...
Damaged fluid pump packings Replace, see page 12 Held open or worn piston or intake Repair; see page 12 valve Exhausted fluid supply Refill and prime Erratic or accelerated operation Fluid intake or piston valve worn Repair; see page 12 309489...
7. Loosen the locknut (15) and unscrew the piston stop pin (24) to a higher or lower set of holes. Use the body (16) from the connecting rod (14). middle holes for medium viscosity fluids. 8. Disassemble and clean all parts. 309489...
With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective.