Thank you for choosing a Quickie Power Chair. We want to We at Sunrise Medical want you to get the best out of your hear your questions or comments about this manual, the wheelchair. This Owner’s Manual will familiarize you with the safety and reliability of your system, and the service you chair and its features.
Contents 5.0 Setting up the seating system ....13 1.0 User information.......... 4 5.1 Pre-set seat width ..........13 1.1 This user manual............ 4 5.2 Pre-set armrests (standard Q700 M Ergo) .... 14 1.2 For further information ......... 4 5.3 Pre-set Leg Rests and footplates (standard 1.3 Symbols used in this manual .........
In case there is no authorized dealer in your area or you have any questions contact Sunrise Medical either in writing or by telephone. For information about product safety notices and product recalls, go to www.SunriseMedical.com...
2.0 Safety Follow the instructions carefully next to these warning symbols! Not paying careful attention to these instructions could result in physical injury or damage to the wheelchair or the environment. Where ver possible, safety information is provided in the relevant chapter. Fig.
If damage is questionable or if there is removable, doing so may result in damage to the concern regarding the condition of the chair, Sunrise Medical seating system or injury to the user. recommends replacement of the chair.
1. Set the speed of the attendant control to a speed that • The vent tray must be installed and maintained by a you can comfortably follow. Sunrise Medical authorized dealer. 2. Always turn off the power to the controller when leaving the user in the chair.
3.0 Warnings for Components and Options 3.5 Positioning belts WARNING! DANGER! • If you use parts or make changes not authorized by The positioning belt is predominately used to support Sunrise it may create a safety hazard and will void the your posture.
3.8 Upholstery fabric 2. Reduced Speed Driving (Creep) This power system is designed to automatically reduce DANGER! the maximum driving speed to a creep mode when certain power seating limits are reached. Depending 1. Replace worn or torn fabric of the seat sling and/or seat on the configuration of the chair there might be back as soon as you possible.
3.12 Power recline 3.16 Swing away joystick arm DANGER! DANGER! Trap Point (pinch point) Before adjusting the swing-away arm, switch off the Avoid putting hands or fingers near the power recline controller to avoid accidental displacement of the joystick mechanism while in operation. which would cause unwanted movement of your Weight Capacity wheelchair.
3.17 Transit: DANGER! Important Transit notes for the chair: If possible and feasible, the rider should transfer to the (OEM) Fig. 3.1 Original Equipment Manufacturer vehicle seat and use the vehicle restraint. If the seating system is used for transport, it must be used in a forward- facing seating position during travel in a motor vehicle.
Authorized Dealer for a thorough inspection. If damage is questionable or if there is concern regarding the condition of the chair, Sunrise Medical recommends replacement of the chair. Wheelchairs involved in collisions should be replaced.
5.0 Setting up the seating system The average wheelchair user does not exist. This is why Sunrise Medical wheelchairs can be adjusted according to specific needs of the user. In this, we make a distinction between wheelchair settings and wheelchair seating adjustment options. Settings are carried out once, the first time the wheelchair is going to be used.
Lift off side cushion The Q700 M Ergo, has the ability to remove the side support cushion without the use of tools. This facilitates side transfers especially when the chair is fitted with lateral knee or hip supports. To remove the side cushion: •...
5.3 Pre-set Leg Rests and footplates (standard Q700 M Ergo) WARNING! • Be aware of your environment to make sure you do not injure your legs when Leg Rests are extended. • Always ensure that the Leg Rests or foot plates do not come into contact with the casters before driving the wheelchair.
When a bigger seat depth is required ensure that the cables are lengthened before the mechanical adjustment takes place. DANGER! We strongly recommend that you contact your Sunrise Medical approved authorized dealer to adjust the seat depth, because adjusting the seat depth will affect the center of gravity.
2. Slide controller (D) to desired height. 3. Tighten screw (C). 5.7 Check after setup and/or adjustment of wheelchair After the initial setup by the Sunrise Medical Authorized Dealer Fig. 5.17 or after making any adjustments to the wheelchair a check to confirm that no interferences exist must be completed.
6.0 Seating positioning accessories 6.1 Lap strap / seating positioning belt (Fig. 6.1). DANGER! • This product is only to be used to position a single person in a wheelchair. • Lap straps are not suitable for transit purposes, approved occupant restraint systems must be used.
Page 19
Positioning a person with a lapstrap DANGER! • Always make sure that the lap strap is correctly secured and adjusted prior to use. • Too loose a strap could cause the user to slip down and cause serious injury. • Check lap strap and securing components at regular intervals for any signs of fray or damage.
7.0 Using the seating system 7.1 Getting in and out of the wheelchair (Transferring) Sunrise Medical recommend that you consult your healthcare professional for assistance in developing your personal front or side transfer technique to best suit your needs and avoid any personal injury.
Page 21
Preparing for side transfer: DANGER! • Move your system as close as you can to the seat you are transferring to. If possible, use a transfer board. • Transfer as far back onto the seat surface as you can. This will reduce the risk that you will miss the seat or fall.
7.2 (Powered) seating option The wheelchair can be equipped with the following powered options to adjust your seating position. These options can be operated by the user without the use of tools. Powered adjustable seating options (Fig. 7.6 - 7.8) How to operate these powered seating options can be found in: ...
7.3 Electric Seating function 7.4 Seat Memory Position The Quickie Q700 M has an electric seating function. This The control system on the Q700 M has up to 6 function is the seat position to which all the Memory seat predefined seat memory positions.
7.5 Retrieving a Memory Seat Position Fig.7.9 (Fig.7.9 to 7.11) Press the ”Mode” button, (A), one or more times until a MODE PROFILE seat icon appears in the LCD control panel display. Move the joystick to the left or right to select a memory seat position (Seating, Supine, Pressure Relief, Feet Above Heart, Transfer, or C-ME®).
Fig.7.12 7.7 Saving a new position to memory 1. Remove the rear cover of the backrest and connect a Switch with a 3.5mm Jack to the socket on the CxSM (Fig. 7.12). 2. Press the ”Mode” button one or more times until a seat icon appears in the LCD control panel display (Fig.7.13).
• Check wheelchair for any broken components, unusual wear, or other indicators of excessive wear. Discontinue Checking seating use if damage is found and contact a Sunrise Medical • Ensure that all the cushions are in place. Authorized dealer. • Make sure that the backrest is correctly fitted and adjusted.Checking connectors and cables:...
Please take into account the manufacturer’s instructions or • A complete inspection, safety check and service should the disinfectant you are using. be made by a Sunrise Medical authorized dealer at least once per year. CAUTION! • All fasteners must be replaced like for like using the •...
* Daily = Before each use of the wheelchair. Quarterly = Every three (3) months. If fasteners are found to be loose a Sunrise Medical Authorized Dealer should tighten the fastener to the torque setting per size detailed below, unless stated otherwise in all appropriate owner’s manuals or installation instructions (if applicable).
9.0 Technical specifications: 9.1 Applicable norms / standards This product complies with the regulations and guidelines or medical aids and carries a CE symbol. The product meets the requirements and standards below. These are checked by independent institution Standard Definition / description Test Dummy Weight EU guideline...
6. WHAT AUTHORIZED DEALER MUST DO - 1. Obtain from Sunrise Medical, while this warranty is in effect, prior approval for return or repair of covered parts. Contact Customer Service for a Returned Material Authorization (RMA) number and information as to where to return the product.