Download Print this page
Broan BU2 SERIES Instructions Manual

Broan BU2 SERIES Instructions Manual

4-way convertible range hood. intended for domestic cooking only

Advertisement

Quick Links

BU2 SERIES
4-WAY CONVERTIBLE
RANGE HOOD
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR INJURY
TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer. If you
have questions, contact the manufacturer at the address or telephone
number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service panel
and lock service disconnecting means to prevent power from being
switched on accidentally. When the service disconnecting means
cannot be locked, securely fasten a prominent warning device, such as
a tag, to the service panel.
3. Installation work and electrical wiring must be done by qualified
personnel in accordance with all applicable codes and standards,
including fire-rated construction codes and standards.
4. Sufficient air is needed for proper combustion and exhausting of
gases through the flue (chimney) of fuel burning equipment to prevent
backdrafting. Follow the heating equipment manufacturer's guidelines
and safety standards such as those published by the National Fire
Protection Association (NFPA) and the American Society for Heating,
Refrigeration and Air Conditioning Engineers (ASHRAE) and the local
code authorities.
5. When cutting or drilling into wall or ceiling, do not damage electrical
wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. Do not use this unit with any additional solid-state speed control device.
8. To reduce the risk of fire, use only metal ductwork.
9. This unit must be grounded.
10. When applicable local regulations comprise more restrictive installation
and/or certification requirements, the aforementioned requirements
prevail on those of this document and the installer agrees to conform to
these at his own expense.
TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE
a) Never leave surface units unattended at high settings. Boilovers cause
smoking and greasy spillovers that may ignite. Heat oils slowly on low
or medium settings.
b) Always turn range hood ON when cooking at high heat or when
flambeing food (i.e.: Crêpes Suzette, Cherries Jubilee, Peppercorn
Beef Flambé).
c) Clean ventilating fans frequently. Grease should not be allowed to
accumulate on fan, filters or in exhaust ducts.
d) Use proper pan size. Always use cookware appropriate for the size of
the surface element.
READ AND SAVE THESE INSTRUCTIONS
!
INTENDED FOR DOMESTIC COOKING ONLY.
INSTALLER: Leave this manual to the homeowner.
HOMEOWNER: Use and care information on page 5.
WARNING
TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT
OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING*:
1. SMOTHER FLAMES with a close-fitting lid, cookie sheet or metal tray,
then turn off the burner. BE CAREFUL TO PREVENT BURNS. IF THE
FLAMES DO NOT GO OUT IMMEDIATELY, EVACUATE AND CALL
THE FIRE DEPARTMENT.
2. NEVER PICK UP A FLAMING PAN — You may be burned.
3. DO NOT USE WATER, including wet dishcloths or towels — This could
cause a violent steam explosion.
4. Use an extinguisher ONLY if:
A. You own a Class ABC extinguisher and you know how to operate it.
B. The fire is small and contained in the area where it started.
C. The fire department has been called.
D. You can fight the fire with your back to an exit.
* Based on "Kitchen Fire Safety Tips" published by NFPA.
!
CAUTION
1. For indoor use only.
2. For general ventilating use only. Do not use to exhaust hazardous or
explosive materials and vapors.
3. To avoid motor bearing damage and noisy and/or unbalanced impellers,
keep drywall spray, construction dust, etc. off power unit.
4. Your hood motor has a thermal overload which will automatically shut
off the motor if it becomes overheated. The motor will restart when it
cools down. If the motor continues to shut off and restart, have the hood
serviced.
5. For best capture of cooking impurities, the bottom of the hood should
be at a minimum of 18" and at a maximum of 24" above the cooking
surface.
6. To reduce the risk of fire and to properly exhaust air, be sure to duct
:
air outside — Donot exhaust air into spaces within walls or ceiling or into
attics, crawl space or garage.
7. When installing, servicing or cleaning the unit, it is recommended to wear
safety glasses and gloves.
8. Please read specification label on product for further information and
requirements.
R
EGISTER YOUR PRODUCT ON LINE AT
.
.
WWW
BROAN
CA
!
99045994A
:

Advertisement

loading

Summary of Contents for Broan BU2 SERIES

  • Page 1 EGISTER YOUR PRODUCT ON LINE AT BROAN BU2 SERIES 4-WAY CONVERTIBLE RANGE HOOD READ AND SAVE THESE INSTRUCTIONS INTENDED FOR DOMESTIC COOKING ONLY. WARNING WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR INJURY TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT...
  • Page 2 IMPORTANT FIG. 1A For Non-ducted (Duct free) Installation: a) Purchase non-ducted filter separately, model 41F. b) Remove and discard damper/duct connector and grille cover (See Step 3 in “Preparing the range Hood,” on page 3). c) Follow all steps except steps inside dotted lines. WALL CAP For Ducted Installation: FIG.
  • Page 3: Preparing The Installation Location

    PREPARING THE RANGE HOOD FIG. 2 KEYHOLE SLOTS 1. Unpack hood and check contents. You should have: 1 - Aluminum filter WIRING BOX COVER 1 - 3¼” x 10” Damper/duct connector (mounted inside of hood for shipping only) (save the screws) 2.
  • Page 4: Installing The Range Hood

    INSTALLING THE DUCTWORK FIG. 9 NOTE THESE INSTRUCTIONS WILL FOLLOW THE PLANS MADE ON PAGE 3. START AT THE EXTERIOR AND RUN THE DUCT BACK TO THE RANGE HOOD. FOR BEST PERFORMANCE OF YOUR RANGE HOOD, USE THE SHORTEST POSSIBLE DUCT RUN AND A MINIMUM NUMBER OF ELBOWS. WALL CAP NEVER VENT A RANGE HOOD INTO AN ATTIC SPACE BECAUSE A BUILDUP OF GREASE WILL BECOME A FIRE HAZARD.
  • Page 5: Filter Removal

    USE AND CARE FIG. 13 SWITCHES The fan and light are each controlled by a rocker switch. The light switch FILTER RETAINING CLIP has two positions, “ON” and “OFF” . The fan switch has three positions - “HIGH” , “LOW” and “OFF” (“OFF” is the middle position). CLEANING Keep your range hood clean using a mild detergent suitable for painted surfaces.
  • Page 6: Service Parts

    SERVICE PARTS BU2 SERIES RANGE HOOD Replacement parts can be ordered by calling 877-896-1119 ESCRIPTION SR680508 7" R OUND DUCTPLATE OPTIONAL PURCHASE SEPARATELY S99150415 N . 8B 1/4" H * (2 EX HEAD SHEET METAL SCREWS REQUIRED S97005544 D AMPER ASSEMBLY...
  • Page 7 Company’s most current written limited warranty for your particular product will control. The most current limited written warranties for the Company’s products can be found at www.broan.ca Venmar Ventilation ULC, 550 Lemire Blvd., Drummondville, Québec, Canada J2C 7W9 www.broan.ca...