Toyotomi Laser 60AT Manual page 34

Vented heater
Hide thumbs Also See for Laser 60AT:
Table of Contents

Advertisement

L A S E R
H E A T I N G
Section 6
6-1 ELECTRICAL SYSTEM
S Y S T E M S
Trouble Shooting
Resistance Values
COMPONENT
Laser 60AT
Igniter (connector G) at cold condition (73˚F (23˚C))
Transformer
Primary Side (connector K)
YL & YL
Secondary Side
BL & BL
Circulation Fan Motor (connector C)
Combustion Blower Motor (connector E)
Thermistor (connector 2 at 77˚F (25˚C))
Fuel Pump (coil)
Component Voltage Readings
COMPONENT
READING TAKEN AT
Laser 60AT
Fuel Pump
OR to BL (A on PCB)
DC 107V
Igniter
G on PCB
AC 120V
Trans-
Primary Side
K on PCB
AC 120V
former
Secondary Side
YL to YL
AC140V
BL to BL
AC 14V
Circulation Fan Motor
C on PCB
High
AC 118V
Motor
Medium
AC 93V
connected
Low
AC 34V
Combustion Blower Motor
E on PCB
High
AC 98V
Motor
Medium
AC 75V
connected
Low
AC 67V
Combustion Blower Motor
RD (+) to BL (-)
DC 5V
Revolution sensor (CN 12)
WH (S) to BL (-) (in operation)
DC 2.5V
S E R V I C E M A N U A L
17
87
470
1.4
450
12
10K
675
31

Advertisement

Table of Contents
loading

Table of Contents