2-9 HEATER INSTALLATION
In choosing a location for your Laser Vented Heater, the
following safety tips must be considered.
• Intake and exhaust flue pipe openings must be
fully exposed to outside air. Do not vent into
garage, basement, under the floor, or into any
enclosed area.
• Do not install flue pipe in close proximity to other
objects or materials. See Figure 2-1.
• Before making a hole in your wall for the flue pipe,
make sure the area is free of electrical wires, gas
pipes and other obstacles.
• Do not install flue pipe where it will be exposed to
heavy snow, collected leaves or strong drafts. See
Figure 2-2.
• Do not install the flue pipe down from the heater.
• Do not install the flue pipe into a chimney.
NOTE:
After using the installation template as a guide
for drilling the flue pipe hole, the Laser flue
pipe can be normally installed according to the
illustration procedure in the Owner's Manual.
If the template was misplaced or the unit is to
be relocated, the approx. flue pipe hole
location measurements are as follows:
5-13/16"
(148mm)
Figure 2-3 TEMPLATE
11
S E R V I C E M A N U A L
H E A T I N G
a. Remove four (4) screws from top plate and remove
b. Remove four (4) screws from canopy guard and
c. Gently insert the ceramic logs into three (3) brackets
5-21/32"
(143mm)
S Y S T E M S
2-10 INSTALLING CERAMIC LOG
the top plate.
Figure 2-4
remove the canopy guard. Remove the heat chamber
lid from the heat exchanger.
Canopy guard
<Canopy Guard>
Figure 2-6
inside of burner properly. After inserting the ceramic
logs, install log supporter on the upper holes of the
ceramic logs. Adjust the log supporter so as to place
the logs at the center of the burner.
Correct
Wrong
Figure 2-8
Installation
Figure 2-5
<Heat Chamber Lid>
Figure 2-7
Log supporter
Top View

Advertisement

Table of Contents
loading