SPECIFICATIONS

2
Item
Function
Capacity
Total input
Service Ref.
Power supply(phase, cycle, voltage)
Input
Running current
Starting current
External finish
Heat exchanger
Fan
Fan(drive) × No.
Fan motor output
Airflow(Low-High)
External static pressure
Booster heater
Operation control & Thermostat
Noise level(Low-High)
Unit drain pipe O.D.
Dimensions
Weight
Service Ref.
Power supply (phase, cycle, voltage)
Input
Running current
Starting current
External finish
Refrigerant control
Compressor
Model
Motor output
Starter type
Protection devices
Heat exchanger
Fan
Fan(drive)×No.
Fan motor output
Airflow
Defrost method
Noise level
Dimensions
Weight
Refrigerant
Charge
Oil<Model>
Pipe size O.D.
Connection method
Between the indoor & outdoor unit
Note1. Rating Conditions (JIS B 8616)
Cooling : Indoor
: D.B. 27°C (80°F), W.B. 19°C (66°F)
Outdoor : D.B. °C (9°F), W.B. 2°C (7°F)
Heating : Indoor
: D.B. 20°C (68°F)
Outdoor : D.B. 7°C (°F), W.B. 6°C (°F)
OC229A
Service Ref.
W
Btu/h
kW
kW
A
A
kW
m
/ <CFM>
3
Pa(mmAq)
kW
(in.)
W
(in.)
D
(in.)
H
(in.)
kg(lbs)
kW
A
A
kW
kW
m
/ <CFM>
3
W
D
(in.)
(in.)
H
(in.)
kg(lbs)
kg(lbs)
L
Liquid
(in.)
Gas
(in.)
Indoor side
Outdoor side
Height difference
Piping length
2. Guaranteed operating range
Cooling
Heating
PKH-1.6GKL
PKH-1.6GKLH
Cooling
4,500
15,350
1.51
PKH-1.6GKL
PKH-1.6GKLH
Single, 50Hz, 220-240V
0.07
0.33
0.40
Munsell 0.70Y 8.59/0.97
Plate fin coil
Line flow(direct) × 1
9-12 (318-424)
0(direct blow)
Remote controller & built-in
20(13/16)
990 (39)
235 (9-1/4)
340 (13-3/8)
16(35) (17(37))
PUH-1.6VKA
Single, 50Hz, 220-240V
1.44
6.74
Munsell 5Y 7/1
Capillary tube
Hermetic
RH247VFC
Line start
Internal thermostat, HP switch
Plate fin coil
Propeller (direct) × 1
45(1,590)
Reverse cycle
870(34-1/4)
295+24(11-5/8 add 1)
650(25-5/8)
53(117)
2.2(4.9)
0.57<MS-56>
9.52(3/8)
15.88(5/8)
Max. 40m
Max. 40m
Upper limit
D.B. 35 , W.B. 22.5
Lower limit
D.B. 21 , W.B. 15.5
Upper limit
Lower limit

Heating
4,650 (5,450)
15,900 (18,600)
1.48 (2.28)
0.07 (0.87)
0.33 (3.66)
0.40 (3.73)
0.030
(0.8)
36-43
2
1.41
6.60
33
1.2
0.065
49
R-22
Flared
Flared
Indoor
Outdoor
D.B. 46
D.B. -5
D.B. 21 , W.B. 15.5
D.B. 27
D.B. 20
D.B. -8.5 , W.B. -9.5