Mains powered room temperature controller featuring straightforward operation.
Self-learning two-position controller providing PID control (patented).
Freely selectable switching times.
Room temperature control in:
– Single-family and holiday houses
– Apartments and office spaces
– Individual rooms and consulting rooms
– Commercially used spaces
For the control of the following pieces of equipment:
– Solenoid valves of instantaneous water heaters
– Solenoid valves of atmospheric gas burners
– Forced draught gas and oil burners
– Circulating pumps in heating systems
– Electric direct heating
– Fans of electric storage heaters
– Zone valves (normally closed)
• PID control
• Self-learning or selectable switching cycle
• Freely adjustable 24-hour mode
• Freely adjustable weekly mode with weekly time switch
• Frost protection function
• Minimum limitation of set point
Room temperature controller, AC 230 V mains powered
without time switch (not soled in this form)
Room temperature controller, AC 230 V mains powered
with analogue 24-hour time switch
Room temperature controller, AC 230 V mains powered
with analogue weekly time switch
Analogue 24-hour time switch
Analogue weekly time switch
When ordering, please give type reference according to "Type summary".
The unit is supplied with all necessary features.
2
226
RAV12...
RAV12
RAV12.1
RAV12.7
AUZ3.1
AUZ3.7
CE1N2226E / 01.02.2000
1/8

Advertisement

Table of Contents
loading

Summary of Contents for Siemens RAV12 series

  • Page 1 Analogue 24-hour time switch AUZ3.1 Analogue weekly time switch AUZ3.7 Ordering When ordering, please give type reference according to "Type summary". Delivery The unit is supplied with all necessary features. Siemens Building Technologies CE1N2226E / 01.02.2000 Landis & Staefa Division...
  • Page 2: Mechanical Design

    • With a connected remote control the unit is overridden from the outside (e.g. by a telephone switch). • When no remote control is connected, the relays is activated and the heating is switched on. CE1N2226E / 01.02.2000 Siemens Building Technologies Landis & Staefa Division...
  • Page 3: Remote Operation

    Operation according to the settings made Continuous economy temperature on the controller 2226Z05 Suitable remote operation units are e.g.: – Telephone modem – manual switch – window switch – presence detector – central unit Siemens Building Technologies CE1N2226E / 01.02.2000 Landis & Staefa Division...
  • Page 4: Technical Features

    However, since - for mechanical reasons - at least two tappets need to be tilted together to set one heat- ing period, the shortest possible heating period is two hours. CE1N2226E / 01.02.2000 Siemens Building Technologies Landis & Staefa Division...
  • Page 5: Technical Data

    3…29 °C Weight 0.2 kg Resolution of analogue time switches Colour White 24-hour time switch 15 min RAL 9003 Weekly time switch 60 min Set point for frost protection 5 °C Siemens Building Technologies CE1N2226E / 01.02.2000 Landis & Staefa Division...
  • Page 6: Connection Diagram

    Atmospheric gas burner Circulating pump with pre-control by manual mixing valve Thermal reset limit thermostat RAV12.. room temperature controller Manual reset safety limit thermostat Manually operated three-port valve Circulating pump Solenoid valve CE1N2226E / 01.02.2000 Siemens Building Technologies Landis & Staefa Division...
  • Page 7 Dimensions Siemens Building Technologies CE1N2226E / 01.02.2000 Landis & Staefa Division...
  • Page 8 © 1999 Siemens Building Technologies Ltd. Subject to change CE1N2226E / 01.02.2000 Siemens Building Technologies Landis & Staefa Division...