Download Print this page

Honeywell Ademco 5800SS1 Installation Manual

Wireless shock sensor
Hide thumbs Also See for Ademco 5800SS1:

Advertisement

Quick Links

GENERAL INFORMATION
The 5800SS1 is a wireless shock sensor
intended for use in systems that support 5800
series devices. Each transmitter has its own
unique
serial
number,
manufacture, which must be "enrolled" in the
control panel before the device can be used
with the system. Refer to the control panel's
Installation and Setup Guide for programming
details.
One 5800SS1 is required for each pane of glass
protected. (Do not use more than one sensor
per pane.)
Types of Glass Protection
Tempered
Ordinary Plate
Laminated Type
Wired
Coated
Sealed Insulated
Note: It is not necessary to remove the case
cover during installation.
ENROLLING THE 5800SS1
You must enroll the 5800SS1 serial number in
the control panel during zone programming.
The control panel's Installation and Setup
Guide
provides
detailed
procedures. Before programming, perform the
following:
1.
To cause the transmitter to transmit,
remove the "PULL TO CONNECT
BATTERY" tab
(see Figure 1).
additional transmissions, lightly tap on
the
base
of
the
screwdriver.)
SENSOR
TAB
PULL TO CONNECT BATTERY
K5867
PULL
Figure 1
www.PDF-Zoo.com
INSTALLATION GUIDE
2.
When programming the shock sensor,
note the following:
assigned
during
3.
When prompted for the serial number,
you can transmit by lightly tapping on the
base of the sensor with a screwdriver or
by manually entering the serial and loop
number.
MOUNTING
1.
Determine
location. For best sensitivity, the sensor
should be mounted one-inch from the
corner edge of the window frame (see
Figure 2).
STRIKE AT
FURTHEST
OPPOSITE
CORNER WITH
SCREWDRIVER
HANDLE
programming
2.
Before the transmitter is permanently
mounted, conduct Go/No Go tests (see
control's instructions) to verify adequate
signal
location.
(For
3.
Always verify range by holding the sensor
in the approximate mounting location and
sensor
with
a
tapping at the base. The panel (in test
mode)
transmissions. If not, find a more suitable
mounting location.
4.
Clean the glass, where the sensor will be
mounted, with a mixture of water and
isopropyl alcohol.
5.
Once the glass has dried, remove the tape
backing paper and firmly press the sensor
in the desired mounting location.
6.
Verify operation by striking the furthest
opposite corner of the glass with the
5800SS1-001-V0
handle of a large screwdriver. Always
check the alarm panel keypad to verify
that the zone has tripped.
K0011 10/01
5800SS1
Wireless Shock Sensor
Input Type = 3 (Supervised RF)
Loop Number = 1
the
optimum
mounting
10 FT. RADIUS
MAXIMUM
COVERAGE
1in.
1in.
MOUNT 1 INCH FROM CORNER
OF WINDOW FRAME.
Figure 2
strength
from
the
mounting
should
respond
to
the

Advertisement

loading

Summary of Contents for Honeywell Ademco 5800SS1

  • Page 1 K0011 10/01 5800SS1 Wireless Shock Sensor INSTALLATION GUIDE GENERAL INFORMATION When programming the shock sensor, note the following: The 5800SS1 is a wireless shock sensor • Input Type = 3 (Supervised RF) intended for use in systems that support 5800 •...
  • Page 2 Apply optional “WARNING” label to the SPECIFICATIONS outside glass surface opposite the tape side Glass Coverage: of the 5800SS1. Plate, Laminate, Wired, Sealed Insulated, Coated and Tempered, up to ¼” (6.35 mm) and 10 ft (3.048 m) distance from mounting REPLACING THE BATTERY location.